GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration
Search

Find a vulnerability

Search criteria

    12 vulnerabilities found for MicroSCADA SYS600 by Hitachi Energy

    CVE-2026-9854 (GCVE-0-2026-9854)

    Vulnerability from nvd – Published: 2026-09-03 07:55 – Updated: 2026-09-03 12:48
    VLAI
    Summary
    A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to administrator level on the underlying Windows host, granting themselves full control over the host machine.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-03 12:48 UTC
    CWE
    • CWE-303 - Incorrect implementation of authentication algorithm
    Assigner
    Impacted products
    Vendor Product Version
    Hitachi Energy MicroSCADA SYS600 Affected: 10.0 , ≤ 10.7 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9854",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-03T12:48:27.499967Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-03T12:48:34.310Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MicroSCADA SYS600",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThanOrEqual": "10.7",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to administrator level on the underlying Windows host, granting themselves full control over the host machine."
                }
              ],
              "value": "A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to administrator level on the underlying Windows host, granting themselves full control over the host machine."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-303",
                  "description": "CWE-303 Incorrect implementation of authentication algorithm",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-03T07:55:05.264Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000249\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2026-9854",
        "datePublished": "2026-09-03T07:55:05.264Z",
        "dateReserved": "2026-05-28T15:04:57.817Z",
        "dateUpdated": "2026-09-03T12:48:34.310Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-9853 (GCVE-0-2026-9853)

    Vulnerability from nvd – Published: 2026-09-03 07:53 – Updated: 2026-09-03 12:49
    VLAI
    Summary
    A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read and modify application objects without being authenticated to the SYS600 system itself. Only the SYS600 system users should be permitted to view and modify application objects.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-03 12:49 UTC
    CWE
    • CWE-303 - Incorrect implementation of authentication algorithm
    Assigner
    Impacted products
    Vendor Product Version
    Hitachi Energy MicroSCADA SYS600 Affected: 10.0 , ≤ 10.8 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9853",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-03T12:49:03.918502Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-03T12:49:23.783Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MicroSCADA SYS600",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThanOrEqual": "10.8",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read and modify application objects without being authenticated to the SYS600 system itself.\n\u003cbr\u003eOnly the SYS600 system users should be permitted to view and modify application objects."
                }
              ],
              "value": "A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read and modify application objects without being authenticated to the SYS600 system itself.\n\nOnly the SYS600 system users should be permitted to view and modify application objects."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-303",
                  "description": "CWE-303 Incorrect implementation of authentication algorithm",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-03T07:53:35.276Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000249\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2026-9853",
        "datePublished": "2026-09-03T07:53:35.276Z",
        "dateReserved": "2026-05-28T15:04:56.583Z",
        "dateUpdated": "2026-09-03T12:49:23.783Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-9852 (GCVE-0-2026-9852)

    Vulnerability from nvd – Published: 2026-09-03 07:53 – Updated: 2026-09-03 12:49
    VLAI
    Summary
    A CSV injection vulnerability exists in SYS600. Injected malicious formulas can add or modify data to the spreadsheet, insert links, exfiltrate data, and in some cases, depending on how the user has their environment configured, execute malicious code on the user’s machine. To exploit this issue attackers would need a way to create arbitrary log messages. This could be achieved through normal functionality via SCIL scripts, a log injection vulnerability, or via the SYS600 broker. This vulnerability affects all Windows users regardless of their privilege level who can run the Notify service and export the log.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-03 12:49 UTC
    CWE
    • CWE-1236 - Improper neutralization of formula elements in a CSV file
    Assigner
    Impacted products
    Vendor Product Version
    Hitachi Energy MicroSCADA SYS600 Affected: 10.0 , ≤ 10.7 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9852",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-03T12:49:34.610302Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-03T12:49:40.825Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MicroSCADA SYS600",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThanOrEqual": "10.7",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A CSV injection vulnerability exists in SYS600. Injected malicious formulas can add or modify data to the spreadsheet, insert links, exfiltrate data, and in some cases, depending on how the user has their environment configured, execute malicious code on the user\u2019s machine. To exploit this issue attackers would need a way to create arbitrary log messages. This could be achieved through normal functionality via SCIL scripts, a log injection vulnerability, or via the SYS600 broker. This vulnerability affects all Windows users regardless of their privilege level who can run the Notify service and export the log."
                }
              ],
              "value": "A CSV injection vulnerability exists in SYS600. Injected malicious formulas can add or modify data to the spreadsheet, insert links, exfiltrate data, and in some cases, depending on how the user has their environment configured, execute malicious code on the user\u2019s machine. To exploit this issue attackers would need a way to create arbitrary log messages. This could be achieved through normal functionality via SCIL scripts, a log injection vulnerability, or via the SYS600 broker. This vulnerability affects all Windows users regardless of their privilege level who can run the Notify service and export the log."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-242",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-242 Code Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 4.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1236",
                  "description": "CWE-1236 Improper neutralization of formula elements in a CSV file",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-03T07:53:06.447Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000249\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2026-9852",
        "datePublished": "2026-09-03T07:53:06.447Z",
        "dateReserved": "2026-05-28T15:04:54.747Z",
        "dateUpdated": "2026-09-03T12:49:40.825Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-7941 (GCVE-0-2024-7941)

    Vulnerability from nvd – Published: 2024-08-27 12:57 – Updated: 2024-08-27 13:12
    VLAI
    Summary
    An HTTP parameter may contain a URL value and could cause the web application to redirect the request to the specified URL. By modifying the URL value to a malicious site, an attacker may successfully launch a phishing scam and steal user credentials.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-27 13:12 UTC
    CWE
    • CWE-601 - URL Redirection to Untrusted Site ('Open Redirect')
    Assigner
    Impacted products
    Vendor Product Version
    Hitachi Energy MicroSCADA SYS600 Affected: 10.0 , ≤ 10.5 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7941",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-27T13:12:50.479278Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-27T13:12:59.267Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MicroSCADA SYS600",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThanOrEqual": "10.5",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An HTTP parameter may contain a URL value and could cause\nthe web application to redirect the request to the specified URL.\nBy modifying the URL value to a malicious site, an attacker may\nsuccessfully launch a phishing scam and steal user credentials."
                }
              ],
              "value": "An HTTP parameter may contain a URL value and could cause\nthe web application to redirect the request to the specified URL.\nBy modifying the URL value to a malicious site, an attacker may\nsuccessfully launch a phishing scam and steal user credentials."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-98",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-98 Phishing"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-601",
                  "description": "CWE-601 URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-27T12:57:55.044Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2024-7941",
        "datePublished": "2024-08-27T12:57:55.044Z",
        "dateReserved": "2024-08-19T14:56:28.496Z",
        "dateUpdated": "2024-08-27T13:12:59.267Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7940 (GCVE-0-2024-7940)

    Vulnerability from nvd – Published: 2024-08-27 12:52 – Updated: 2024-08-27 13:43
    VLAI
    Summary
    The product exposes a service that is intended for local only to all network interfaces without any authentication.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-27 13:26 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    Hitachi Energy MicroSCADA SYS600 Affected: 10.2 , ≤ 10.5 (custom)
    Create a notification for this product.
    hitachienergy microscada_x_sys600 Affected: 10.2 , ≤ 10.5 (custom)
        cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "microscada_x_sys600",
                "vendor": "hitachienergy",
                "versions": [
                  {
                    "lessThanOrEqual": "10.5",
                    "status": "affected",
                    "version": "10.2",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7940",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-27T13:26:16.109923Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-27T13:43:15.252Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MicroSCADA SYS600",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThanOrEqual": "10.5",
                  "status": "affected",
                  "version": "10.2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The product exposes a service that is intended for local only to\nall network interfaces without any authentication."
                }
              ],
              "value": "The product exposes a service that is intended for local only to\nall network interfaces without any authentication."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-27T12:52:54.589Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2024-7940",
        "datePublished": "2024-08-27T12:52:24.601Z",
        "dateReserved": "2024-08-19T14:56:24.826Z",
        "dateUpdated": "2024-08-27T13:43:15.252Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-3982 (GCVE-0-2024-3982)

    Vulnerability from nvd – Published: 2024-08-27 12:47 – Updated: 2024-08-27 17:52
    VLAI
    Summary
    An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level is not enabled and only users with administrator rights can enable it.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-27 17:49 UTC
    CWE
    • CWE-294 - Authentication Bypass by Capture-replay
    Assigner
    Impacted products
    Vendor Product Version
    Hitachi Energy MicroSCADA SYS600 Affected: 10.0 , ≤ 10.5 (custom)
    Create a notification for this product.
    hitachi microscada_x_sys600 Affected: 10.0 , ≤ 10.5 (custom)
        cpe:2.3:a:hitachi:microscada_x_sys600:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:hitachi:microscada_x_sys600:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "microscada_x_sys600",
                "vendor": "hitachi",
                "versions": [
                  {
                    "lessThanOrEqual": "10.5",
                    "status": "affected",
                    "version": "10.0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-3982",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-27T17:49:48.661304Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-27T17:52:18.269Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MicroSCADA SYS600",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThanOrEqual": "10.5",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An attacker with local access to machine where MicroSCADA X\nSYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level\nis not enabled and only users with administrator rights can enable it."
                }
              ],
              "value": "An attacker with local access to machine where MicroSCADA X\nSYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level\nis not enabled and only users with administrator rights can enable it."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-593",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-593 Session Hijacking"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-294",
                  "description": "CWE-294 Authentication Bypass by Capture-replay",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-27T12:47:21.577Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2024-3982",
        "datePublished": "2024-08-27T12:47:21.577Z",
        "dateReserved": "2024-04-19T12:47:07.829Z",
        "dateUpdated": "2024-08-27T17:52:18.269Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-9854 (GCVE-0-2026-9854)

    Vulnerability from cvelistv5 – Published: 2026-09-03 07:55 – Updated: 2026-09-03 12:48
    VLAI
    Summary
    A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to administrator level on the underlying Windows host, granting themselves full control over the host machine.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-03 12:48 UTC
    CWE
    • CWE-303 - Incorrect implementation of authentication algorithm
    Assigner
    Impacted products
    Vendor Product Version
    Hitachi Energy MicroSCADA SYS600 Affected: 10.0 , ≤ 10.7 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9854",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-03T12:48:27.499967Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-03T12:48:34.310Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MicroSCADA SYS600",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThanOrEqual": "10.7",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to administrator level on the underlying Windows host, granting themselves full control over the host machine."
                }
              ],
              "value": "A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to administrator level on the underlying Windows host, granting themselves full control over the host machine."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-303",
                  "description": "CWE-303 Incorrect implementation of authentication algorithm",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-03T07:55:05.264Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000249\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2026-9854",
        "datePublished": "2026-09-03T07:55:05.264Z",
        "dateReserved": "2026-05-28T15:04:57.817Z",
        "dateUpdated": "2026-09-03T12:48:34.310Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-9853 (GCVE-0-2026-9853)

    Vulnerability from cvelistv5 – Published: 2026-09-03 07:53 – Updated: 2026-09-03 12:49
    VLAI
    Summary
    A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read and modify application objects without being authenticated to the SYS600 system itself. Only the SYS600 system users should be permitted to view and modify application objects.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-03 12:49 UTC
    CWE
    • CWE-303 - Incorrect implementation of authentication algorithm
    Assigner
    Impacted products
    Vendor Product Version
    Hitachi Energy MicroSCADA SYS600 Affected: 10.0 , ≤ 10.8 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9853",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-03T12:49:03.918502Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-03T12:49:23.783Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MicroSCADA SYS600",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThanOrEqual": "10.8",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read and modify application objects without being authenticated to the SYS600 system itself.\n\u003cbr\u003eOnly the SYS600 system users should be permitted to view and modify application objects."
                }
              ],
              "value": "A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read and modify application objects without being authenticated to the SYS600 system itself.\n\nOnly the SYS600 system users should be permitted to view and modify application objects."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 8.5,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-303",
                  "description": "CWE-303 Incorrect implementation of authentication algorithm",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-03T07:53:35.276Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000249\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2026-9853",
        "datePublished": "2026-09-03T07:53:35.276Z",
        "dateReserved": "2026-05-28T15:04:56.583Z",
        "dateUpdated": "2026-09-03T12:49:23.783Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-9852 (GCVE-0-2026-9852)

    Vulnerability from cvelistv5 – Published: 2026-09-03 07:53 – Updated: 2026-09-03 12:49
    VLAI
    Summary
    A CSV injection vulnerability exists in SYS600. Injected malicious formulas can add or modify data to the spreadsheet, insert links, exfiltrate data, and in some cases, depending on how the user has their environment configured, execute malicious code on the user’s machine. To exploit this issue attackers would need a way to create arbitrary log messages. This could be achieved through normal functionality via SCIL scripts, a log injection vulnerability, or via the SYS600 broker. This vulnerability affects all Windows users regardless of their privilege level who can run the Notify service and export the log.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-03 12:49 UTC
    CWE
    • CWE-1236 - Improper neutralization of formula elements in a CSV file
    Assigner
    Impacted products
    Vendor Product Version
    Hitachi Energy MicroSCADA SYS600 Affected: 10.0 , ≤ 10.7 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-9852",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-03T12:49:34.610302Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-03T12:49:40.825Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MicroSCADA SYS600",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThanOrEqual": "10.7",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A CSV injection vulnerability exists in SYS600. Injected malicious formulas can add or modify data to the spreadsheet, insert links, exfiltrate data, and in some cases, depending on how the user has their environment configured, execute malicious code on the user\u2019s machine. To exploit this issue attackers would need a way to create arbitrary log messages. This could be achieved through normal functionality via SCIL scripts, a log injection vulnerability, or via the SYS600 broker. This vulnerability affects all Windows users regardless of their privilege level who can run the Notify service and export the log."
                }
              ],
              "value": "A CSV injection vulnerability exists in SYS600. Injected malicious formulas can add or modify data to the spreadsheet, insert links, exfiltrate data, and in some cases, depending on how the user has their environment configured, execute malicious code on the user\u2019s machine. To exploit this issue attackers would need a way to create arbitrary log messages. This could be achieved through normal functionality via SCIL scripts, a log injection vulnerability, or via the SYS600 broker. This vulnerability affects all Windows users regardless of their privilege level who can run the Notify service and export the log."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-242",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-242 Code Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 4.6,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "LOW",
                "subIntegrityImpact": "LOW",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1236",
                  "description": "CWE-1236 Improper neutralization of formula elements in a CSV file",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-03T07:53:06.447Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000249\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2026-9852",
        "datePublished": "2026-09-03T07:53:06.447Z",
        "dateReserved": "2026-05-28T15:04:54.747Z",
        "dateUpdated": "2026-09-03T12:49:40.825Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2024-7941 (GCVE-0-2024-7941)

    Vulnerability from cvelistv5 – Published: 2024-08-27 12:57 – Updated: 2024-08-27 13:12
    VLAI
    Summary
    An HTTP parameter may contain a URL value and could cause the web application to redirect the request to the specified URL. By modifying the URL value to a malicious site, an attacker may successfully launch a phishing scam and steal user credentials.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-27 13:12 UTC
    CWE
    • CWE-601 - URL Redirection to Untrusted Site ('Open Redirect')
    Assigner
    Impacted products
    Vendor Product Version
    Hitachi Energy MicroSCADA SYS600 Affected: 10.0 , ≤ 10.5 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7941",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-27T13:12:50.479278Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-27T13:12:59.267Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MicroSCADA SYS600",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThanOrEqual": "10.5",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An HTTP parameter may contain a URL value and could cause\nthe web application to redirect the request to the specified URL.\nBy modifying the URL value to a malicious site, an attacker may\nsuccessfully launch a phishing scam and steal user credentials."
                }
              ],
              "value": "An HTTP parameter may contain a URL value and could cause\nthe web application to redirect the request to the specified URL.\nBy modifying the URL value to a malicious site, an attacker may\nsuccessfully launch a phishing scam and steal user credentials."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-98",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-98 Phishing"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-601",
                  "description": "CWE-601 URL Redirection to Untrusted Site (\u0027Open Redirect\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-27T12:57:55.044Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2024-7941",
        "datePublished": "2024-08-27T12:57:55.044Z",
        "dateReserved": "2024-08-19T14:56:28.496Z",
        "dateUpdated": "2024-08-27T13:12:59.267Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-7940 (GCVE-0-2024-7940)

    Vulnerability from cvelistv5 – Published: 2024-08-27 12:52 – Updated: 2024-08-27 13:43
    VLAI
    Summary
    The product exposes a service that is intended for local only to all network interfaces without any authentication.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-27 13:26 UTC
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    Impacted products
    Vendor Product Version
    Hitachi Energy MicroSCADA SYS600 Affected: 10.2 , ≤ 10.5 (custom)
    Create a notification for this product.
    hitachienergy microscada_x_sys600 Affected: 10.2 , ≤ 10.5 (custom)
        cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "microscada_x_sys600",
                "vendor": "hitachienergy",
                "versions": [
                  {
                    "lessThanOrEqual": "10.5",
                    "status": "affected",
                    "version": "10.2",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-7940",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-27T13:26:16.109923Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-27T13:43:15.252Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MicroSCADA SYS600",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThanOrEqual": "10.5",
                  "status": "affected",
                  "version": "10.2",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The product exposes a service that is intended for local only to\nall network interfaces without any authentication."
                }
              ],
              "value": "The product exposes a service that is intended for local only to\nall network interfaces without any authentication."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-27T12:52:54.589Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2024-7940",
        "datePublished": "2024-08-27T12:52:24.601Z",
        "dateReserved": "2024-08-19T14:56:24.826Z",
        "dateUpdated": "2024-08-27T13:43:15.252Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-3982 (GCVE-0-2024-3982)

    Vulnerability from cvelistv5 – Published: 2024-08-27 12:47 – Updated: 2024-08-27 17:52
    VLAI
    Summary
    An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level is not enabled and only users with administrator rights can enable it.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-08-27 17:49 UTC
    CWE
    • CWE-294 - Authentication Bypass by Capture-replay
    Assigner
    Impacted products
    Vendor Product Version
    Hitachi Energy MicroSCADA SYS600 Affected: 10.0 , ≤ 10.5 (custom)
    Create a notification for this product.
    hitachi microscada_x_sys600 Affected: 10.0 , ≤ 10.5 (custom)
        cpe:2.3:a:hitachi:microscada_x_sys600:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:hitachi:microscada_x_sys600:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "microscada_x_sys600",
                "vendor": "hitachi",
                "versions": [
                  {
                    "lessThanOrEqual": "10.5",
                    "status": "affected",
                    "version": "10.0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-3982",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-27T17:49:48.661304Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-27T17:52:18.269Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "MicroSCADA SYS600",
              "vendor": "Hitachi Energy",
              "versions": [
                {
                  "lessThanOrEqual": "10.5",
                  "status": "affected",
                  "version": "10.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An attacker with local access to machine where MicroSCADA X\nSYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level\nis not enabled and only users with administrator rights can enable it."
                }
              ],
              "value": "An attacker with local access to machine where MicroSCADA X\nSYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level\nis not enabled and only users with administrator rights can enable it."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-593",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-593 Session Hijacking"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-294",
                  "description": "CWE-294 Authentication Bypass by Capture-replay",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-08-27T12:47:21.577Z",
            "orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
            "shortName": "Hitachi Energy"
          },
          "references": [
            {
              "url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
        "assignerShortName": "Hitachi Energy",
        "cveId": "CVE-2024-3982",
        "datePublished": "2024-08-27T12:47:21.577Z",
        "dateReserved": "2024-04-19T12:47:07.829Z",
        "dateUpdated": "2024-08-27T17:52:18.269Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",