Search criteria
3 vulnerabilities found for EA7500 by Linksys
VAR-202405-0739
Vulnerability from variot - Updated: 2025-07-09 23:22Buffer Overflow vulnerability LINKSYS EA7500 3.0.1.207964 allows a remote attacker to execute arbitrary code via an HTTP request to the IGD UPnP. Linksys of EA7500 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Linksys EA7500 is a wireless router from Linksys, Inc. of the United States. The vulnerability is caused by a boundary error when the application processes untrusted input
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202405-0739",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "ea7500",
"scope": "eq",
"trust": 1.6,
"vendor": "linksys",
"version": "3.0.1.207964"
},
{
"model": "ea7500",
"scope": null,
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "ea7500",
"scope": "eq",
"trust": 0.8,
"vendor": "linksys",
"version": null
},
{
"model": "ea7500",
"scope": "eq",
"trust": 0.8,
"vendor": "linksys",
"version": "ea7500 firmware 3.0.1.207964"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02168"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-029261"
},
{
"db": "NVD",
"id": "CVE-2023-46012"
}
]
},
"cve": "CVE-2023-46012",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-02168",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-46012",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2023-029261",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2023-46012",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "OTHER",
"id": "JVNDB-2023-029261",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2025-02168",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02168"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-029261"
},
{
"db": "NVD",
"id": "CVE-2023-46012"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Buffer Overflow vulnerability LINKSYS EA7500 3.0.1.207964 allows a remote attacker to execute arbitrary code via an HTTP request to the IGD UPnP. Linksys of EA7500 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Linksys EA7500 is a wireless router from Linksys, Inc. of the United States. The vulnerability is caused by a boundary error when the application processes untrusted input",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-46012"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-029261"
},
{
"db": "CNVD",
"id": "CNVD-2025-02168"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-46012",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-029261",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-02168",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02168"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-029261"
},
{
"db": "NVD",
"id": "CVE-2023-46012"
}
]
},
"id": "VAR-202405-0739",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02168"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02168"
}
]
},
"last_update_date": "2025-07-09T23:22:29.095000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-120",
"trust": 1.0
},
{
"problemtype": "Classic buffer overflow (CWE-120) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-029261"
},
{
"db": "NVD",
"id": "CVE-2023-46012"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/dest-3/cve-2023-46012/tree/main"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-46012"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-02168"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-029261"
},
{
"db": "NVD",
"id": "CVE-2023-46012"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-02168"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-029261"
},
{
"db": "NVD",
"id": "CVE-2023-46012"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-01-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-02168"
},
{
"date": "2025-07-07T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-029261"
},
{
"date": "2024-05-07T14:15:10.003000",
"db": "NVD",
"id": "CVE-2023-46012"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-01-22T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-02168"
},
{
"date": "2025-07-07T08:10:00",
"db": "JVNDB",
"id": "JVNDB-2023-029261"
},
{
"date": "2025-06-30T17:22:55.067000",
"db": "NVD",
"id": "CVE-2023-46012"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Linksys\u00a0 of \u00a0EA7500\u00a0 Classic buffer overflow vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-029261"
}
],
"trust": 0.8
}
}
CVE-2025-6752 (GCVE-0-2025-6752)
Vulnerability from nvd – Published: 2025-06-27 03:31 – Updated: 2025-06-27 14:20
VLAI?
Title
Linksys WRT1900ACS/EA7200/EA7450/EA7500 IGD Layer3Forwarding SetDefaultConnectionService stack-based overflow
Summary
A vulnerability has been found in Linksys WRT1900ACS, EA7200, EA7450 and EA7500 up to 20250619 and classified as critical. This vulnerability affects the function SetDefaultConnectionService of the file /upnp/control/Layer3Forwarding of the component IGD. The manipulation of the argument NewDefaultConnectionService leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
Credits
starash (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6752",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-27T14:19:53.625787Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-27T14:20:16.274Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"IGD"
],
"product": "WRT1900ACS",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "20250619"
}
]
},
{
"modules": [
"IGD"
],
"product": "EA7200",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "20250619"
}
]
},
{
"modules": [
"IGD"
],
"product": "EA7450",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "20250619"
}
]
},
{
"modules": [
"IGD"
],
"product": "EA7500",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "20250619"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "starash (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Linksys WRT1900ACS, EA7200, EA7450 and EA7500 up to 20250619 and classified as critical. This vulnerability affects the function SetDefaultConnectionService of the file /upnp/control/Layer3Forwarding of the component IGD. The manipulation of the argument NewDefaultConnectionService leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Linksys WRT1900ACS, EA7200, EA7450 and EA7500 bis 20250619 wurde eine kritische Schwachstelle gefunden. Es geht um die Funktion SetDefaultConnectionService der Datei /upnp/control/Layer3Forwarding der Komponente IGD. Dank der Manipulation des Arguments NewDefaultConnectionService mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-27T03:31:06.429Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-314050 | Linksys WRT1900ACS/EA7200/EA7450/EA7500 IGD Layer3Forwarding SetDefaultConnectionService stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.314050"
},
{
"name": "VDB-314050 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.314050"
},
{
"name": "Submit #600638 | Linksys WRT1900ACS Ver. 2.0.3.201002 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.600638"
},
{
"tags": [
"related"
],
"url": "https://github.com/feiwuxingxie/cve/blob/main/linksys/vul01/1.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/feiwuxingxie/cve/blob/main/linksys/vul01/1.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.linksys.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-26T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-26T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-26T22:19:04.000Z",
"value": "VulDB entry last update"
}
],
"title": "Linksys WRT1900ACS/EA7200/EA7450/EA7500 IGD Layer3Forwarding SetDefaultConnectionService stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-6752",
"datePublished": "2025-06-27T03:31:06.429Z",
"dateReserved": "2025-06-26T20:13:50.409Z",
"dateUpdated": "2025-06-27T14:20:16.274Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-6752 (GCVE-0-2025-6752)
Vulnerability from cvelistv5 – Published: 2025-06-27 03:31 – Updated: 2025-06-27 14:20
VLAI?
Title
Linksys WRT1900ACS/EA7200/EA7450/EA7500 IGD Layer3Forwarding SetDefaultConnectionService stack-based overflow
Summary
A vulnerability has been found in Linksys WRT1900ACS, EA7200, EA7450 and EA7500 up to 20250619 and classified as critical. This vulnerability affects the function SetDefaultConnectionService of the file /upnp/control/Layer3Forwarding of the component IGD. The manipulation of the argument NewDefaultConnectionService leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
Assigner
References
| URL | Tags | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
Impacted products
Credits
starash (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-6752",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-27T14:19:53.625787Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-27T14:20:16.274Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"modules": [
"IGD"
],
"product": "WRT1900ACS",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "20250619"
}
]
},
{
"modules": [
"IGD"
],
"product": "EA7200",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "20250619"
}
]
},
{
"modules": [
"IGD"
],
"product": "EA7450",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "20250619"
}
]
},
{
"modules": [
"IGD"
],
"product": "EA7500",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "20250619"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "starash (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Linksys WRT1900ACS, EA7200, EA7450 and EA7500 up to 20250619 and classified as critical. This vulnerability affects the function SetDefaultConnectionService of the file /upnp/control/Layer3Forwarding of the component IGD. The manipulation of the argument NewDefaultConnectionService leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "In Linksys WRT1900ACS, EA7200, EA7450 and EA7500 bis 20250619 wurde eine kritische Schwachstelle gefunden. Es geht um die Funktion SetDefaultConnectionService der Datei /upnp/control/Layer3Forwarding der Komponente IGD. Dank der Manipulation des Arguments NewDefaultConnectionService mit unbekannten Daten kann eine stack-based buffer overflow-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 9,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Memory Corruption",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-27T03:31:06.429Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-314050 | Linksys WRT1900ACS/EA7200/EA7450/EA7500 IGD Layer3Forwarding SetDefaultConnectionService stack-based overflow",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.314050"
},
{
"name": "VDB-314050 | CTI Indicators (IOB, IOC, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.314050"
},
{
"name": "Submit #600638 | Linksys WRT1900ACS Ver. 2.0.3.201002 Stack-based Buffer Overflow",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.600638"
},
{
"tags": [
"related"
],
"url": "https://github.com/feiwuxingxie/cve/blob/main/linksys/vul01/1.md"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/feiwuxingxie/cve/blob/main/linksys/vul01/1.md#poc"
},
{
"tags": [
"product"
],
"url": "https://www.linksys.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-26T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-26T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-26T22:19:04.000Z",
"value": "VulDB entry last update"
}
],
"title": "Linksys WRT1900ACS/EA7200/EA7450/EA7500 IGD Layer3Forwarding SetDefaultConnectionService stack-based overflow"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-6752",
"datePublished": "2025-06-27T03:31:06.429Z",
"dateReserved": "2025-06-26T20:13:50.409Z",
"dateUpdated": "2025-06-27T14:20:16.274Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",