Search criteria
4 vulnerabilities found for AppSpider by Rapid7
CVE-2020-7358 (GCVE-0-2020-7358)
Vulnerability from nvd – Published: 2020-09-18 14:55 – Updated: 2024-08-04 09:25
VLAI?
Title
Code Injection in Rapid7 AppSpider Pro Installer
Summary
In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name.
Severity ?
5.8 (Medium)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
Credits
This issue was discovered and reported by Mishra Dhiraj.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:25:48.976Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AppSpider ",
"vendor": "Rapid7",
"versions": [
{
"lessThan": "7.2.126",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This issue was discovered and reported by Mishra Dhiraj. "
}
],
"descriptions": [
{
"lang": "en",
"value": "In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-18T14:55:12",
"orgId": "9974b330-7714-4307-a722-5648477acda7",
"shortName": "rapid7"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Code Injection in Rapid7 AppSpider Pro Installer",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@rapid7.com",
"ID": "CVE-2020-7358",
"STATE": "PUBLIC",
"TITLE": "Code Injection in Rapid7 AppSpider Pro Installer"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AppSpider ",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "7.2.126"
}
]
}
}
]
},
"vendor_name": "Rapid7"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "This issue was discovered and reported by Mishra Dhiraj. "
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427 Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126",
"refsource": "MISC",
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
"assignerShortName": "rapid7",
"cveId": "CVE-2020-7358",
"datePublished": "2020-09-18T14:55:12",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:25:48.976Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-5647 (GCVE-0-2019-5647)
Vulnerability from nvd – Published: 2020-01-22 18:00 – Updated: 2024-09-17 00:51
VLAI?
Title
Rapid7 AppSpider Chrome Plugin Insufficient Session Expiration
Summary
The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215.
Severity ?
4.4 (Medium)
CWE
- CWE-613 - Insufficient Session Expiration
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:01:52.069Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AppSpider",
"vendor": "Rapid7",
"versions": [
{
"lessThanOrEqual": "3.8.213",
"status": "affected",
"version": "3.8.213",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-08-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-613",
"description": "CWE-613 Insufficient Session Expiration",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-22T18:00:22",
"orgId": "9974b330-7714-4307-a722-5648477acda7",
"shortName": "rapid7"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
}
],
"source": {
"discovery": "USER"
},
"title": "Rapid7 AppSpider Chrome Plugin Insufficient Session Expiration",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@rapid7.com",
"DATE_PUBLIC": "2019-08-20T14:00:00.000Z",
"ID": "CVE-2019-5647",
"STATE": "PUBLIC",
"TITLE": "Rapid7 AppSpider Chrome Plugin Insufficient Session Expiration"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AppSpider",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "3.8.213",
"version_value": "3.8.213"
}
]
}
}
]
},
"vendor_name": "Rapid7"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-613 Insufficient Session Expiration"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215",
"refsource": "CONFIRM",
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
}
]
},
"source": {
"discovery": "USER"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
"assignerShortName": "rapid7",
"cveId": "CVE-2019-5647",
"datePublished": "2020-01-22T18:00:22.724972Z",
"dateReserved": "2019-01-07T00:00:00",
"dateUpdated": "2024-09-17T00:51:55.819Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-7358 (GCVE-0-2020-7358)
Vulnerability from cvelistv5 – Published: 2020-09-18 14:55 – Updated: 2024-08-04 09:25
VLAI?
Title
Code Injection in Rapid7 AppSpider Pro Installer
Summary
In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name.
Severity ?
5.8 (Medium)
CWE
- CWE-427 - Uncontrolled Search Path Element
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
Credits
This issue was discovered and reported by Mishra Dhiraj.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:25:48.976Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AppSpider ",
"vendor": "Rapid7",
"versions": [
{
"lessThan": "7.2.126",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This issue was discovered and reported by Mishra Dhiraj. "
}
],
"descriptions": [
{
"lang": "en",
"value": "In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-427",
"description": "CWE-427 Uncontrolled Search Path Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-18T14:55:12",
"orgId": "9974b330-7714-4307-a722-5648477acda7",
"shortName": "rapid7"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Code Injection in Rapid7 AppSpider Pro Installer",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@rapid7.com",
"ID": "CVE-2020-7358",
"STATE": "PUBLIC",
"TITLE": "Code Injection in Rapid7 AppSpider Pro Installer"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AppSpider ",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "7.2.126"
}
]
}
}
]
},
"vendor_name": "Rapid7"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "This issue was discovered and reported by Mishra Dhiraj. "
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In AppSpider installer versions prior to 7.2.126, the AppSpider installer calls an executable which can be placed in the appropriate directory by an attacker with access to the local machine. This would prevent the installer from distinguishing between a valid executable called during an installation and any arbitrary code executable using the same file name."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-427 Uncontrolled Search Path Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126",
"refsource": "MISC",
"url": "https://help.rapid7.com/appspider/release-notes/index.html?pid=7.2.126"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
"assignerShortName": "rapid7",
"cveId": "CVE-2020-7358",
"datePublished": "2020-09-18T14:55:12",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:25:48.976Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-5647 (GCVE-0-2019-5647)
Vulnerability from cvelistv5 – Published: 2020-01-22 18:00 – Updated: 2024-09-17 00:51
VLAI?
Title
Rapid7 AppSpider Chrome Plugin Insufficient Session Expiration
Summary
The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215.
Severity ?
4.4 (Medium)
CWE
- CWE-613 - Insufficient Session Expiration
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:01:52.069Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "AppSpider",
"vendor": "Rapid7",
"versions": [
{
"lessThanOrEqual": "3.8.213",
"status": "affected",
"version": "3.8.213",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-08-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-613",
"description": "CWE-613 Insufficient Session Expiration",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-22T18:00:22",
"orgId": "9974b330-7714-4307-a722-5648477acda7",
"shortName": "rapid7"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
}
],
"source": {
"discovery": "USER"
},
"title": "Rapid7 AppSpider Chrome Plugin Insufficient Session Expiration",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@rapid7.com",
"DATE_PUBLIC": "2019-08-20T14:00:00.000Z",
"ID": "CVE-2019-5647",
"STATE": "PUBLIC",
"TITLE": "Rapid7 AppSpider Chrome Plugin Insufficient Session Expiration"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "AppSpider",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "3.8.213",
"version_value": "3.8.213"
}
]
}
}
]
},
"vendor_name": "Rapid7"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Chrome Plugin for Rapid7 AppSpider can incorrectly keep browser sessions active after recording a macro, even after a restart of the Chrome browser. This behavior could make future session hijacking attempts easier, since the user could believe a session was closed when it was not. This issue affects Rapid7 AppSpider version 3.8.213 and prior versions, and is fixed in version 3.8.215."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 4.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-613 Insufficient Session Expiration"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215",
"refsource": "CONFIRM",
"url": "https://help.rapid7.com/appspiderenterprise/release-notes/?rid=3.8.215"
}
]
},
"source": {
"discovery": "USER"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
"assignerShortName": "rapid7",
"cveId": "CVE-2019-5647",
"datePublished": "2020-01-22T18:00:22.724972Z",
"dateReserved": "2019-01-07T00:00:00",
"dateUpdated": "2024-09-17T00:51:55.819Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}