Search criteria

6 vulnerabilities found for Access Professional Edition by Bosch

VAR-201905-0315

Vulnerability from variot - Updated: 2024-11-23 22:25

A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as "CWE-284: Improper Access Control." This vulnerability, for example, allows a potential attacker to delete video or read video data. plural Bosch The product contains an access control vulnerability.Information is obtained and service operation is interrupted (DoS) There is a possibility of being put into a state. Bosch DIVAR IP 2000 and so on are all products of Bosch Company in Germany. Bosch DIVAR IP 2000 is a 2000 series video recorder. Video Recording Manager (VRM) is a video recording manager. Bosch DIVAR IP 3000 is a 3000 series video recorder. An access control error vulnerability exists in several Bosch products. This vulnerability stems from network systems or products not properly restricting access to resources from unauthorized roles

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201905-0315",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "access easy controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "2.1.9.3"
      },
      {
        "model": "video client",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "1.7.6.079"
      },
      {
        "model": "configuration manager",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "6.10"
      },
      {
        "model": "building integration system",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "2.2"
      },
      {
        "model": "access professional edition",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "3.0"
      },
      {
        "model": "access easy controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "2.1.9.1"
      },
      {
        "model": "access easy controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "2.1.8.5"
      },
      {
        "model": "building integration system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "4.6.1"
      },
      {
        "model": "dip 7000",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": null
      },
      {
        "model": "dip 3000",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": null
      },
      {
        "model": "building integration system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "4.5"
      },
      {
        "model": "video sdk",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "6.32.0099"
      },
      {
        "model": "dip 2000",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "0380.037"
      },
      {
        "model": "building integration system",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "4.4"
      },
      {
        "model": "building integration system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "4.6"
      },
      {
        "model": "access easy controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "2.1.9.0"
      },
      {
        "model": "access professional edition",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "3.7"
      },
      {
        "model": "dip 5000",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "038.037"
      },
      {
        "model": "video management system",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "9.0"
      },
      {
        "model": "access easy controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "access professional edition",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "video client",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "video management system",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "building integration system",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "configuration manager",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "divar ip 2000",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "divar ip 3000",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "divar ip 5000",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "divar ip 7000",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "video sdk",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004954"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6958"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:bosch:access_easy_controller_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:bosch:access_professional_edition",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:bosch:bosch_video_client",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:bosch:video_recording_manager",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:bosch:building_integration_system",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:bosch:configuration_manager",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:bosch:divar_ip_2000_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:bosch:dip_3000_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:bosch:divar_ip_5000_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:bosch:dip_7000_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:bosch:video_sdk",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004954"
      }
    ]
  },
  "cve": "CVE-2019-6958",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-6958",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 6.4,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2019-6958",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-158393",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-6958",
            "impactScore": 5.2,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cve@mitre.org",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-6958",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.1,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2019-6958",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-6958",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "cve@mitre.org",
            "id": "CVE-2019-6958",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-6958",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201905-1061",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-158393",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158393"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004954"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1061"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6958"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6958"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The RCP+ network port allows access without authentication. Adding authentication feature to the respective library fixes the issue. The issue is classified as \"CWE-284: Improper Access Control.\" This vulnerability, for example, allows a potential attacker to delete video or read video data. plural Bosch The product contains an access control vulnerability.Information is obtained and service operation is interrupted (DoS) There is a possibility of being put into a state. Bosch DIVAR IP 2000 and so on are all products of Bosch Company in Germany. Bosch DIVAR IP 2000 is a 2000 series video recorder. Video Recording Manager (VRM) is a video recording manager. Bosch DIVAR IP 3000 is a 3000 series video recorder. An access control error vulnerability exists in several Bosch products. This vulnerability stems from network systems or products not properly restricting access to resources from unauthorized roles",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-6958"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004954"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158393"
      }
    ],
    "trust": 1.71
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-6958",
        "trust": 2.5
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004954",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1061",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-158393",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158393"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004954"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1061"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6958"
      }
    ]
  },
  "id": "VAR-201905-0315",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158393"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2024-11-23T22:25:56.536000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "BOSCH-2019-0404-BT",
        "trust": 0.8,
        "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
      },
      {
        "title": "Multiple Bosch Product access control error vulnerability fixes",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=93014"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004954"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1061"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-306",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-284",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158393"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004954"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6958"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0404bt-cve-2019-6958_security_advisory_improper_access_control.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6958"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6958"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158393"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004954"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1061"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6958"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-158393"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004954"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1061"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6958"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158393"
      },
      {
        "date": "2019-06-12T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004954"
      },
      {
        "date": "2019-05-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-1061"
      },
      {
        "date": "2019-05-29T19:29:00.703000",
        "db": "NVD",
        "id": "CVE-2019-6958"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2023-01-31T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158393"
      },
      {
        "date": "2019-06-12T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004954"
      },
      {
        "date": "2020-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-1061"
      },
      {
        "date": "2024-11-21T04:47:18.280000",
        "db": "NVD",
        "id": "CVE-2019-6958"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1061"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Bosch Access control vulnerabilities in products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004954"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "access control error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1061"
      }
    ],
    "trust": 0.6
  }
}

VAR-201905-0314

Vulnerability from variot - Updated: 2024-11-23 22:21

A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface. plural Bosch The product contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Bosch DIVAR IP 2000 and so on are all products of Bosch Company in Germany. Bosch DIVAR IP 2000 is a 2000 series video recorder. Video Recording Manager (VRM) is a video recording manager. Bosch DIVAR IP 3000 is a 3000 series video recorder. A buffer overflow vulnerability exists in several Bosch products. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201905-0314",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "access easy controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "2.1.9.3"
      },
      {
        "model": "video client",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "1.7.6.079"
      },
      {
        "model": "video recording manager",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "3.81"
      },
      {
        "model": "configuration manager",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "6.10"
      },
      {
        "model": "building integration system",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "2.2"
      },
      {
        "model": "access professional edition",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "3.0"
      },
      {
        "model": "access easy controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "2.1.9.1"
      },
      {
        "model": "video recording manager",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "3.71.0032"
      },
      {
        "model": "video streaming gateway",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "6.43.0023"
      },
      {
        "model": "video streaming gateway",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "6.45"
      },
      {
        "model": "video streaming gateway",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "6.45.0008"
      },
      {
        "model": "access easy controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "2.1.8.5"
      },
      {
        "model": "building integration system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "4.6.1"
      },
      {
        "model": "dip 7000",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": null
      },
      {
        "model": "dip 3000",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": null
      },
      {
        "model": "building integration system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "4.5"
      },
      {
        "model": "video recording manager",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "3.81.0048"
      },
      {
        "model": "video sdk",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "6.32.0099"
      },
      {
        "model": "dip 2000",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "0380.037"
      },
      {
        "model": "building integration system",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "4.4"
      },
      {
        "model": "building integration system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "4.6"
      },
      {
        "model": "access easy controller",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "2.1.9.0"
      },
      {
        "model": "access professional edition",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "3.7"
      },
      {
        "model": "dip 5000",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "038.037"
      },
      {
        "model": "video management system",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "bosch",
        "version": "9.0"
      },
      {
        "model": "access easy controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "access professional edition",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "video client",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "video management system",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "building integration system",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "configuration manager",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "divar ip 3000",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "divar ip 7000",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "video sdk",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      },
      {
        "model": "video streaming gateway",
        "scope": null,
        "trust": 0.8,
        "vendor": "robert bosch",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004953"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6957"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:bosch:access_easy_controller_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:bosch:access_professional_edition",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:bosch:bosch_video_client",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:bosch:video_recording_manager",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:bosch:building_integration_system",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:bosch:configuration_manager",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:bosch:dip_3000_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:bosch:dip_7000_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:bosch:video_sdk",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:bosch:video_streaming_gateway",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004953"
      }
    ]
  },
  "cve": "CVE-2019-6957",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-6957",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-158392",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "cve@mitre.org",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-6957",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-6957",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-6957",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "cve@mitre.org",
            "id": "CVE-2019-6957",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-6957",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201905-1062",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-158392",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2019-6957",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158392"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6957"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004953"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1062"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6957"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6957"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A recently discovered security vulnerability affects all Bosch Video Management System (BVMS) versions 9.0 and below, DIVAR IP 2000, 3000, 5000 and 7000, Video Recording Manager (VRM), Video Streaming Gateway (VSG), Configuration Manager, Building Integration System (BIS) with Video Engine, Access Professional Edition (APE), Access Easy Controller (AEC), Bosch Video Client (BVC) and Video SDK (VSDK). The vulnerability potentially allows the unauthorized execution of code in the system via the network interface. plural Bosch The product contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Bosch DIVAR IP 2000 and so on are all products of Bosch Company in Germany. Bosch DIVAR IP 2000 is a 2000 series video recorder. Video Recording Manager (VRM) is a video recording manager. Bosch DIVAR IP 3000 is a 3000 series video recorder. A buffer overflow vulnerability exists in several Bosch products. This vulnerability stems from the incorrect verification of data boundaries when the network system or product performs operations on the memory, resulting in incorrect read and write operations to other associated memory locations. Attackers can exploit this vulnerability to cause buffer overflow or heap overflow, etc",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-6957"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004953"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158392"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6957"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-6957",
        "trust": 2.6
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004953",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1062",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-158392",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6957",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158392"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6957"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004953"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1062"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6957"
      }
    ]
  },
  "id": "VAR-201905-0314",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158392"
      }
    ],
    "trust": 0.01
  },
  "last_update_date": "2024-11-23T22:21:41.401000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "BOSCH-2019-0403-BT",
        "trust": 0.8,
        "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
      },
      {
        "title": "Multiple Bosch Product Buffer Error Vulnerability Fix",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=93015"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004953"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1062"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-119",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158392"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004953"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6957"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.8,
        "url": "https://media.boschsecurity.com/fs/media/pb/security_advisories/bosch-2019-0403bt-cve-2019-6957_security_advisory_software_buffer_overflow.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6957"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6957"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/787.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158392"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6957"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004953"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1062"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6957"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-158392"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6957"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004953"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1062"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6957"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158392"
      },
      {
        "date": "2019-05-29T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-6957"
      },
      {
        "date": "2019-06-12T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004953"
      },
      {
        "date": "2019-05-29T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-1062"
      },
      {
        "date": "2019-05-29T19:29:00.657000",
        "db": "NVD",
        "id": "CVE-2019-6957"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-11-30T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158392"
      },
      {
        "date": "2022-11-30T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-6957"
      },
      {
        "date": "2019-06-12T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004953"
      },
      {
        "date": "2020-08-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-1062"
      },
      {
        "date": "2024-11-21T04:47:18.127000",
        "db": "NVD",
        "id": "CVE-2019-6957"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1062"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Bosch Product buffer error vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004953"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-1062"
      }
    ],
    "trust": 0.6
  }
}

CVE-2019-11899 (GCVE-0-2019-11899)

Vulnerability from nvd – Published: 2019-09-12 18:30 – Updated: 2024-09-17 02:17
VLAI?
Summary
An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Bosch Access Professional Edition Affected: unspecified , ≤ 3.7 (custom)
Create a notification for this product.
Credits
Oleksii Orekhov
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.632Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Professional Edition",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "3.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Oleksii Orekhov"
        }
      ],
      "datePublic": "2019-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-12T18:30:58",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-09-11T00:00:00.000Z",
          "ID": "CVE-2019-11899",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Professional Edition",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Oleksii Orekhov"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11899",
    "datePublished": "2019-09-12T18:30:58.728052Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-17T02:17:02.364Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-11898 (GCVE-0-2019-11898)

Vulnerability from nvd – Published: 2019-09-12 18:23 – Updated: 2024-09-17 04:09
VLAI?
Summary
Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
Vendor Product Version
Bosch Access Professional Edition Affected: unspecified , ≤ 3.7 (custom)
Create a notification for this product.
Credits
Oleksii Orekhov
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.542Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Professional Edition",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "3.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Oleksii Orekhov"
        }
      ],
      "datePublic": "2019-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-12T18:23:21",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-09-11T00:00:00.000Z",
          "ID": "CVE-2019-11898",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Professional Edition",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Oleksii Orekhov"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798 Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11898",
    "datePublished": "2019-09-12T18:23:21.989608Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-17T04:09:20.767Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-11899 (GCVE-0-2019-11899)

Vulnerability from cvelistv5 – Published: 2019-09-12 18:30 – Updated: 2024-09-17 02:17
VLAI?
Summary
An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator.
CWE
  • CWE-284 - Improper Access Control
Assigner
References
Impacted products
Vendor Product Version
Bosch Access Professional Edition Affected: unspecified , ≤ 3.7 (custom)
Create a notification for this product.
Credits
Oleksii Orekhov
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.632Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Professional Edition",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "3.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Oleksii Orekhov"
        }
      ],
      "datePublic": "2019-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-284",
              "description": "CWE-284 Improper Access Control",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-12T18:30:58",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-09-11T00:00:00.000Z",
          "ID": "CVE-2019-11899",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Professional Edition",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Oleksii Orekhov"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An unauthenticated attacker can achieve unauthorized access to sensitive data by exploiting Windows SMB protocol on a client installation. With Bosch Access Professional Edition (APE) 3.8, client installations need to be authorized by the APE administrator."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-284 Improper Access Control"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-844044.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11899",
    "datePublished": "2019-09-12T18:30:58.728052Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-17T02:17:02.364Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-11898 (GCVE-0-2019-11898)

Vulnerability from cvelistv5 – Published: 2019-09-12 18:23 – Updated: 2024-09-17 04:09
VLAI?
Summary
Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
Vendor Product Version
Bosch Access Professional Edition Affected: unspecified , ≤ 3.7 (custom)
Create a notification for this product.
Credits
Oleksii Orekhov
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T23:10:29.542Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Access Professional Edition",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "3.7",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Oleksii Orekhov"
        }
      ],
      "datePublic": "2019-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-12T18:23:21",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2019-09-11T00:00:00.000Z",
          "ID": "CVE-2019-11898",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Access Professional Edition",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.7"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Oleksii Orekhov"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Unauthorized APE administration privileges can be achieved by reverse engineering one of the APE service tools. The service tool is discontinued with Bosch Access Professional Edition (APE) 3.8."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.9,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798 Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/Advisory/BOSCH-SA-710832.html"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2019-11898",
    "datePublished": "2019-09-12T18:23:21.989608Z",
    "dateReserved": "2019-05-13T00:00:00",
    "dateUpdated": "2024-09-17T04:09:20.767Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}