Search

Find a vulnerability

Search criteria

    20 vulnerabilities found for 752-8303\/8000-002_firmware by wago

    CVE-2022-45140 (GCVE-0-2022-45140)

    Vulnerability from nvd – Published: 2023-02-27 14:36 – Updated: 2025-03-10 17:46
    VLAI
    Title
    WAGO: Missing Authentication for Critical Function
    Summary
    The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:55.436Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45140",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-10T17:46:43.476712Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-10T17:46:52.078Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise."
                }
              ],
              "value": "The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:39.448Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Missing Authentication for Critical Function ",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45140",
        "datePublished": "2023-02-27T14:36:39.448Z",
        "dateReserved": "2022-11-10T09:46:59.080Z",
        "dateUpdated": "2025-03-10T17:46:52.078Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45139 (GCVE-0-2022-45139)

    Vulnerability from nvd – Published: 2023-02-27 14:36 – Updated: 2025-03-10 17:46
    VLAI
    Title
    WAGO: Origin validation error through CORS misconfiguration
    Summary
    A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-346 - Origin Validation Error
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW18 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:55.406Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45139",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-10T17:45:54.261351Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-10T17:46:16.888Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality."
                }
              ],
              "value": "A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-554",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-554 Functionality Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-346",
                  "description": "CWE-346 Origin Validation Error",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:32.016Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Origin validation error through CORS misconfiguration",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45139",
        "datePublished": "2023-02-27T14:36:32.016Z",
        "dateReserved": "2022-11-10T09:46:59.080Z",
        "dateUpdated": "2025-03-10T17:46:16.888Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45138 (GCVE-0-2022-45138)

    Vulnerability from nvd – Published: 2023-02-27 14:36 – Updated: 2025-03-10 17:20
    VLAI
    Title
    WAGO: Missing Authentication for Critical Function
    Summary
    The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW18 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:55.415Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45138",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-10T17:20:33.215201Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-10T17:20:50.798Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device."
                }
              ],
              "value": "The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:20.474Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Missing Authentication for Critical Function",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45138",
        "datePublished": "2023-02-27T14:36:20.474Z",
        "dateReserved": "2022-11-10T09:46:59.079Z",
        "dateUpdated": "2025-03-10T17:20:50.798Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45137 (GCVE-0-2022-45137)

    Vulnerability from nvd – Published: 2023-02-27 14:36 – Updated: 2024-08-03 14:09
    VLAI
    Title
    WAGO: Reflective Cross-Site Scripting
    Summary
    The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability.
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW18 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:56.545Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability."
                }
              ],
              "value": "The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-63",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-63 Cross-Site Scripting (XSS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:03.411Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Reflective Cross-Site Scripting",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45137",
        "datePublished": "2023-02-27T14:36:03.411Z",
        "dateReserved": "2022-11-10T09:46:59.079Z",
        "dateUpdated": "2024-08-03T14:09:56.545Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34569 (GCVE-0-2021-34569)

    Vulnerability from nvd – Published: 2022-11-09 15:17 – Updated: 2025-05-01 19:17
    VLAI
    Title
    WAGO I/O-Check Service prone to Out-of-bounds Write
    Summary
    In WAGO I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-81xx/xxx-xxxFW Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 750-82xx/xxx-xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 752-8303/8000-0002 Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-4xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-5xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-6xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    Date Public
    2021-06-29 10:00
    Credits
    These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:12:50.524Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-34569",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-01T19:17:25.396965Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-01T19:17:39.712Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "750-81xx/xxx-xxxFW",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-82xx/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "752-8303/8000-0002",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-4xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-5xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-6xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
            }
          ],
          "datePublic": "2021-06-29T10:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory."
                }
              ],
              "value": "In WAGO\u00a0I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-123",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-123 Buffer Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-09T15:17:36.366Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
            }
          ],
          "source": {
            "advisory": "VDE-2020-036",
            "discovery": "EXTERNAL"
          },
          "title": "WAGO I/O-Check Service prone to Out-of-bounds Write",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34569",
        "datePublished": "2022-11-09T15:17:36.366Z",
        "dateReserved": "2021-06-10T19:19:08.023Z",
        "dateUpdated": "2025-05-01T19:17:39.712Z",
        "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34568 (GCVE-0-2021-34568)

    Vulnerability from nvd – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:20
    VLAI
    Title
    WAGO I/O-Check Service prone to Allocation of Resources Without Limits or Throttling
    Summary
    In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-770 - Allocation of Resources Without Limits or Throttling
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-81xx/xxx-xxxFW Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 750-82xx/xxx-xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 752-8303/8000-0002 Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-4xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-5xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-6xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    Date Public
    2021-06-29 10:00
    Credits
    These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:12:50.423Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-34568",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-01T14:20:11.257503Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-01T14:20:17.218Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "750-81xx/xxx-xxxFW",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-82xx/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "752-8303/8000-0002",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-4xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-5xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-6xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
            }
          ],
          "datePublic": "2021-06-29T10:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service."
                }
              ],
              "value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-130",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-130 Excessive Allocation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-770",
                  "description": "CWE-770 Allocation of Resources Without Limits or Throttling",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-09T15:17:29.795Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
            }
          ],
          "source": {
            "advisory": "VDE-2020-036",
            "discovery": "EXTERNAL"
          },
          "title": "WAGO I/O-Check Service prone to Allocation of Resources Without Limits or Throttling",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34568",
        "datePublished": "2022-11-09T15:17:29.795Z",
        "dateReserved": "2021-06-10T19:19:08.023Z",
        "dateUpdated": "2025-05-01T14:20:17.218Z",
        "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34567 (GCVE-0-2021-34567)

    Vulnerability from nvd – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:20
    VLAI
    Title
    WAGO I/O-Check Service prone to Out-of-bounds Read
    Summary
    In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-81xx/xxx-xxxFW Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 750-82xx/xxx-xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 752-8303/8000-0002 Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-4xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-5xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-6xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    Date Public
    2021-06-29 10:00
    Credits
    These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:12:50.416Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-34567",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-01T14:20:33.137134Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-01T14:20:39.270Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "750-81xx/xxx-xxxFW",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-82xx/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "752-8303/8000-0002",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-4xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-5xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-6xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
            }
          ],
          "datePublic": "2021-06-29T10:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read."
                }
              ],
              "value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-540",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-540 Overread Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-09T15:17:23.429Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
            }
          ],
          "source": {
            "advisory": "VDE-2020-036",
            "discovery": "EXTERNAL"
          },
          "title": "WAGO I/O-Check Service prone to Out-of-bounds Read",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34567",
        "datePublished": "2022-11-09T15:17:23.429Z",
        "dateReserved": "2021-06-10T19:19:08.023Z",
        "dateUpdated": "2025-05-01T14:20:39.270Z",
        "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34566 (GCVE-0-2021-34566)

    Vulnerability from nvd – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:21
    VLAI
    Title
    WAGO I/O-Check Service prone to Memory Overflow
    Summary
    In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-81xx/xxx-xxxFW Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 750-82xx/xxx-xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 752-8303/8000-0002 Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-4xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-5xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-6xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    Date Public
    2021-06-29 10:00
    Credits
    These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:12:50.402Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-34566",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-01T14:21:03.913921Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-01T14:21:10.643Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "750-81xx/xxx-xxxFW",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-82xx/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "752-8303/8000-0002",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-4xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-5xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-6xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
            }
          ],
          "datePublic": "2021-06-29T10:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS."
                }
              ],
              "value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-09T15:17:14.172Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
            }
          ],
          "source": {
            "advisory": "VDE-2020-036",
            "discovery": "EXTERNAL"
          },
          "title": "WAGO I/O-Check Service prone to Memory Overflow",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34566",
        "datePublished": "2022-11-09T15:17:14.172Z",
        "dateReserved": "2021-06-10T19:19:08.023Z",
        "dateUpdated": "2025-05-01T14:21:10.643Z",
        "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-3281 (GCVE-0-2022-3281)

    Vulnerability from nvd – Published: 2022-10-17 08:20 – Updated: 2025-05-10 02:56
    VLAI
    Title
    WAGO: multiple products - Loss of MAC-Address-Filtering after reboot
    Summary
    WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-440 - Expected Behavior Violation
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-81xx/xxx-xxx Series PFC100/PFC200 Affected: 03.01.07(13) , ≤ 03.10.08(22) (custom)
    Create a notification for this product.
    WAGO 750-8217/xxx-xxx Series PFC100/PFC200 Affected: 03.04.10(16) , ≤ 03.10.08(22) (custom)
    Create a notification for this product.
    WAGO 750-82xx/xxx-xxx Series PFC100/PFC200 Affected: 03.01.07(13) , ≤ 03.10.08(22) (custom)
    Create a notification for this product.
    WAGO Compact Controller CC100 Affected: 03.07.17(19) , ≤ 03.09.08(21) (custom)
    Create a notification for this product.
    WAGO 762-4xxx Series Touch Panel 600 Affected: 03.01.07(13) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    WAGO 762-5xxx Series Touch Panel 600 Affected: 03.01.07(13) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    WAGO 762-6xxx Series Touch Panel 600 Affected: 03.01.07(13) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    WAGO 752-8303/8000-002 Edge Controller Affected: 03.06.09(18) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    Date Public
    2022-10-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T01:07:06.534Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-3281",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-10T02:56:08.488527Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-10T02:56:32.932Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "750-81xx/xxx-xxx Series PFC100/PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.08(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-8217/xxx-xxx Series PFC100/PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.08(22)",
                  "status": "affected",
                  "version": "03.04.10(16)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-82xx/xxx-xxx Series PFC100/PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.08(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Compact Controller CC100",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.09.08(21)",
                  "status": "affected",
                  "version": "03.07.17(19)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "762-4xxx Series Touch Panel 600",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "762-5xxx Series Touch Panel 600",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "762-6xxx Series Touch Panel 600",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "752-8303/8000-002 Edge Controller",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.06.09(18)",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-10-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-440",
                  "description": "CWE-440 Expected Behavior Violation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-02T00:00:00.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
            }
          ],
          "source": {
            "advisory": "VDE-2022-042",
            "defect": [
              "CERT@VDE#64236"
            ],
            "discovery": "INTERNAL"
          },
          "title": "WAGO: multiple products - Loss of MAC-Address-Filtering after reboot",
          "x_generator": {
            "engine": "vulnogram 0.1.0-rc1"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-3281",
        "datePublished": "2022-10-17T08:20:12.389Z",
        "dateReserved": "2022-09-23T00:00:00.000Z",
        "dateUpdated": "2025-05-10T02:56:32.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-22511 (GCVE-0-2022-22511)

    Vulnerability from nvd – Published: 2022-03-09 19:38 – Updated: 2024-09-17 00:16
    VLAI
    Title
    WAGO PLCs WBM vulnerable to reflected XSS
    Summary
    Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised.
    CWE
    • CWE-79 - Cross-site Scripting (XSS)
    Assigner
    References
    Date Public
    2022-03-09 00:00
    Credits
    These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T03:14:55.300Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Series PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Series PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Series Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW16 FW22"
                }
              ]
            },
            {
              "product": "Series Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW16 FW22"
                }
              ]
            },
            {
              "product": "Series Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW16 FW22"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
            }
          ],
          "datePublic": "2022-03-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Cross-site Scripting (XSS)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-09T19:38:43.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
            }
          ],
          "source": {
            "advisory": "VDE-2022-004",
            "defect": [
              "CERT@VDE#64068"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "WAGO PLCs WBM vulnerable to reflected XSS",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2022-03-09T07:00:00.000Z",
              "ID": "CVE-2022-22511",
              "STATE": "PUBLIC",
              "TITLE": "WAGO PLCs WBM vulnerable to reflected XSS"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Compact Controller CC100 (751-9301)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Edge Controller (752-8303/8000-002)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series PFC100 (750-81xx/xxx-xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series PFC200 (750-82xx/xxx-xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series Touch Panel 600 Advanced Line (762-5xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series Touch Panel 600 Marine Line (762-6xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series Touch Panel 600 Standard Line (762-4xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "WAGO"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79 Cross-site Scripting (XSS)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert.vde.com/en/advisories/VDE-2022-004/",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
              }
            ],
            "source": {
              "advisory": "VDE-2022-004",
              "defect": [
                "CERT@VDE#64068"
              ],
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-22511",
        "datePublished": "2022-03-09T19:38:43.516Z",
        "dateReserved": "2022-01-03T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:16:00.059Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45140 (GCVE-0-2022-45140)

    Vulnerability from cvelistv5 – Published: 2023-02-27 14:36 – Updated: 2025-03-10 17:46
    VLAI
    Title
    WAGO: Missing Authentication for Critical Function
    Summary
    The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:55.436Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45140",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-10T17:46:43.476712Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-10T17:46:52.078Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise."
                }
              ],
              "value": "The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:39.448Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Missing Authentication for Critical Function ",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45140",
        "datePublished": "2023-02-27T14:36:39.448Z",
        "dateReserved": "2022-11-10T09:46:59.080Z",
        "dateUpdated": "2025-03-10T17:46:52.078Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45139 (GCVE-0-2022-45139)

    Vulnerability from cvelistv5 – Published: 2023-02-27 14:36 – Updated: 2025-03-10 17:46
    VLAI
    Title
    WAGO: Origin validation error through CORS misconfiguration
    Summary
    A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-346 - Origin Validation Error
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW18 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:55.406Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45139",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-10T17:45:54.261351Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-10T17:46:16.888Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality."
                }
              ],
              "value": "A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-554",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-554 Functionality Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-346",
                  "description": "CWE-346 Origin Validation Error",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:32.016Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Origin validation error through CORS misconfiguration",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45139",
        "datePublished": "2023-02-27T14:36:32.016Z",
        "dateReserved": "2022-11-10T09:46:59.080Z",
        "dateUpdated": "2025-03-10T17:46:16.888Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45138 (GCVE-0-2022-45138)

    Vulnerability from cvelistv5 – Published: 2023-02-27 14:36 – Updated: 2025-03-10 17:20
    VLAI
    Title
    WAGO: Missing Authentication for Critical Function
    Summary
    The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW18 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:55.415Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45138",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-10T17:20:33.215201Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-10T17:20:50.798Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device."
                }
              ],
              "value": "The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:20.474Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Missing Authentication for Critical Function",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45138",
        "datePublished": "2023-02-27T14:36:20.474Z",
        "dateReserved": "2022-11-10T09:46:59.079Z",
        "dateUpdated": "2025-03-10T17:20:50.798Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45137 (GCVE-0-2022-45137)

    Vulnerability from cvelistv5 – Published: 2023-02-27 14:36 – Updated: 2024-08-03 14:09
    VLAI
    Title
    WAGO: Reflective Cross-Site Scripting
    Summary
    The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability.
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW18 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:56.545Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability."
                }
              ],
              "value": "The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-63",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-63 Cross-Site Scripting (XSS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:03.411Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Reflective Cross-Site Scripting",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45137",
        "datePublished": "2023-02-27T14:36:03.411Z",
        "dateReserved": "2022-11-10T09:46:59.079Z",
        "dateUpdated": "2024-08-03T14:09:56.545Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34569 (GCVE-0-2021-34569)

    Vulnerability from cvelistv5 – Published: 2022-11-09 15:17 – Updated: 2025-05-01 19:17
    VLAI
    Title
    WAGO I/O-Check Service prone to Out-of-bounds Write
    Summary
    In WAGO I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-81xx/xxx-xxxFW Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 750-82xx/xxx-xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 752-8303/8000-0002 Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-4xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-5xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-6xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    Date Public
    2021-06-29 10:00
    Credits
    These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:12:50.524Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-34569",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-01T19:17:25.396965Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-01T19:17:39.712Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "750-81xx/xxx-xxxFW",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-82xx/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "752-8303/8000-0002",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-4xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-5xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-6xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
            }
          ],
          "datePublic": "2021-06-29T10:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory."
                }
              ],
              "value": "In WAGO\u00a0I/O-Check Service in multiple products an attacker can send a specially crafted packet containing OS commands to crash the diagnostic tool and write memory."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-123",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-123 Buffer Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-09T15:17:36.366Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
            }
          ],
          "source": {
            "advisory": "VDE-2020-036",
            "discovery": "EXTERNAL"
          },
          "title": "WAGO I/O-Check Service prone to Out-of-bounds Write",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34569",
        "datePublished": "2022-11-09T15:17:36.366Z",
        "dateReserved": "2021-06-10T19:19:08.023Z",
        "dateUpdated": "2025-05-01T19:17:39.712Z",
        "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34568 (GCVE-0-2021-34568)

    Vulnerability from cvelistv5 – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:20
    VLAI
    Title
    WAGO I/O-Check Service prone to Allocation of Resources Without Limits or Throttling
    Summary
    In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-770 - Allocation of Resources Without Limits or Throttling
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-81xx/xxx-xxxFW Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 750-82xx/xxx-xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 752-8303/8000-0002 Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-4xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-5xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-6xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    Date Public
    2021-06-29 10:00
    Credits
    These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:12:50.423Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-34568",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-01T14:20:11.257503Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-01T14:20:17.218Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "750-81xx/xxx-xxxFW",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-82xx/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "752-8303/8000-0002",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-4xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-5xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-6xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
            }
          ],
          "datePublic": "2021-06-29T10:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service."
                }
              ],
              "value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-130",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-130 Excessive Allocation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-770",
                  "description": "CWE-770 Allocation of Resources Without Limits or Throttling",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-09T15:17:29.795Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
            }
          ],
          "source": {
            "advisory": "VDE-2020-036",
            "discovery": "EXTERNAL"
          },
          "title": "WAGO I/O-Check Service prone to Allocation of Resources Without Limits or Throttling",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34568",
        "datePublished": "2022-11-09T15:17:29.795Z",
        "dateReserved": "2021-06-10T19:19:08.023Z",
        "dateUpdated": "2025-05-01T14:20:17.218Z",
        "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34567 (GCVE-0-2021-34567)

    Vulnerability from cvelistv5 – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:20
    VLAI
    Title
    WAGO I/O-Check Service prone to Out-of-bounds Read
    Summary
    In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-81xx/xxx-xxxFW Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 750-82xx/xxx-xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 752-8303/8000-0002 Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-4xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-5xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-6xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    Date Public
    2021-06-29 10:00
    Credits
    These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:12:50.416Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-34567",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-01T14:20:33.137134Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-01T14:20:39.270Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "750-81xx/xxx-xxxFW",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-82xx/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "752-8303/8000-0002",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-4xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-5xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-6xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
            }
          ],
          "datePublic": "2021-06-29T10:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read."
                }
              ],
              "value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to provoke a denial of service and an limited out-of-bounds read."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-540",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-540 Overread Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-09T15:17:23.429Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
            }
          ],
          "source": {
            "advisory": "VDE-2020-036",
            "discovery": "EXTERNAL"
          },
          "title": "WAGO I/O-Check Service prone to Out-of-bounds Read",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34567",
        "datePublished": "2022-11-09T15:17:23.429Z",
        "dateReserved": "2021-06-10T19:19:08.023Z",
        "dateUpdated": "2025-05-01T14:20:39.270Z",
        "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34566 (GCVE-0-2021-34566)

    Vulnerability from cvelistv5 – Published: 2022-11-09 15:17 – Updated: 2025-05-01 14:21
    VLAI
    Title
    WAGO I/O-Check Service prone to Memory Overflow
    Summary
    In WAGO I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-81xx/xxx-xxxFW Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 750-82xx/xxx-xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 752-8303/8000-0002 Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-4xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-5xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    WAGO 762-6xxx Affected: FW1 , ≤ FW18 Patch 2 (custom)
    Create a notification for this product.
    Date Public
    2021-06-29 10:00
    Credits
    These vulnerabilities were reported to WAGO by Uri Katz of Claroty.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:12:50.402Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-34566",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-01T14:21:03.913921Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-01T14:21:10.643Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "750-81xx/xxx-xxxFW",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-82xx/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "752-8303/8000-0002",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-4xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-5xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "762-6xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW18 Patch 2",
                  "status": "affected",
                  "version": "FW1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "These vulnerabilities were reported to WAGO by Uri Katz of Claroty."
            }
          ],
          "datePublic": "2021-06-29T10:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "In WAGO\u0026nbsp;I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS."
                }
              ],
              "value": "In WAGO\u00a0I/O-Check Service in multiple products an unauthenticated remote attacker can send a specially crafted packet containing OS commands to crash the iocheck process and write memory resulting in loss of integrity and DoS."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-09T15:17:14.172Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2020-036/"
            }
          ],
          "source": {
            "advisory": "VDE-2020-036",
            "discovery": "EXTERNAL"
          },
          "title": "WAGO I/O-Check Service prone to Memory Overflow",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34566",
        "datePublished": "2022-11-09T15:17:14.172Z",
        "dateReserved": "2021-06-10T19:19:08.023Z",
        "dateUpdated": "2025-05-01T14:21:10.643Z",
        "requesterUserId": "520cc88b-a1c8-44f6-9154-21a4d74c769f",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-3281 (GCVE-0-2022-3281)

    Vulnerability from cvelistv5 – Published: 2022-10-17 08:20 – Updated: 2025-05-10 02:56
    VLAI
    Title
    WAGO: multiple products - Loss of MAC-Address-Filtering after reboot
    Summary
    WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-440 - Expected Behavior Violation
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-81xx/xxx-xxx Series PFC100/PFC200 Affected: 03.01.07(13) , ≤ 03.10.08(22) (custom)
    Create a notification for this product.
    WAGO 750-8217/xxx-xxx Series PFC100/PFC200 Affected: 03.04.10(16) , ≤ 03.10.08(22) (custom)
    Create a notification for this product.
    WAGO 750-82xx/xxx-xxx Series PFC100/PFC200 Affected: 03.01.07(13) , ≤ 03.10.08(22) (custom)
    Create a notification for this product.
    WAGO Compact Controller CC100 Affected: 03.07.17(19) , ≤ 03.09.08(21) (custom)
    Create a notification for this product.
    WAGO 762-4xxx Series Touch Panel 600 Affected: 03.01.07(13) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    WAGO 762-5xxx Series Touch Panel 600 Affected: 03.01.07(13) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    WAGO 762-6xxx Series Touch Panel 600 Affected: 03.01.07(13) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    WAGO 752-8303/8000-002 Edge Controller Affected: 03.06.09(18) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    Date Public
    2022-10-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T01:07:06.534Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-3281",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-10T02:56:08.488527Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-10T02:56:32.932Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "750-81xx/xxx-xxx Series PFC100/PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.08(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-8217/xxx-xxx Series PFC100/PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.08(22)",
                  "status": "affected",
                  "version": "03.04.10(16)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-82xx/xxx-xxx Series PFC100/PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.08(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Compact Controller CC100",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.09.08(21)",
                  "status": "affected",
                  "version": "03.07.17(19)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "762-4xxx Series Touch Panel 600",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "762-5xxx Series Touch Panel 600",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "762-6xxx Series Touch Panel 600",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "752-8303/8000-002 Edge Controller",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.06.09(18)",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-10-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-440",
                  "description": "CWE-440 Expected Behavior Violation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-02T00:00:00.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
            }
          ],
          "source": {
            "advisory": "VDE-2022-042",
            "defect": [
              "CERT@VDE#64236"
            ],
            "discovery": "INTERNAL"
          },
          "title": "WAGO: multiple products - Loss of MAC-Address-Filtering after reboot",
          "x_generator": {
            "engine": "vulnogram 0.1.0-rc1"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-3281",
        "datePublished": "2022-10-17T08:20:12.389Z",
        "dateReserved": "2022-09-23T00:00:00.000Z",
        "dateUpdated": "2025-05-10T02:56:32.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-22511 (GCVE-0-2022-22511)

    Vulnerability from cvelistv5 – Published: 2022-03-09 19:38 – Updated: 2024-09-17 00:16
    VLAI
    Title
    WAGO PLCs WBM vulnerable to reflected XSS
    Summary
    Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised.
    CWE
    • CWE-79 - Cross-site Scripting (XSS)
    Assigner
    References
    Date Public
    2022-03-09 00:00
    Credits
    These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T03:14:55.300Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Series PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Series PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Series Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW16 FW22"
                }
              ]
            },
            {
              "product": "Series Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW16 FW22"
                }
              ]
            },
            {
              "product": "Series Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW16 FW22"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
            }
          ],
          "datePublic": "2022-03-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Cross-site Scripting (XSS)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-09T19:38:43.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
            }
          ],
          "source": {
            "advisory": "VDE-2022-004",
            "defect": [
              "CERT@VDE#64068"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "WAGO PLCs WBM vulnerable to reflected XSS",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2022-03-09T07:00:00.000Z",
              "ID": "CVE-2022-22511",
              "STATE": "PUBLIC",
              "TITLE": "WAGO PLCs WBM vulnerable to reflected XSS"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Compact Controller CC100 (751-9301)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Edge Controller (752-8303/8000-002)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series PFC100 (750-81xx/xxx-xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series PFC200 (750-82xx/xxx-xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series Touch Panel 600 Advanced Line (762-5xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series Touch Panel 600 Marine Line (762-6xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series Touch Panel 600 Standard Line (762-4xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "WAGO"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79 Cross-site Scripting (XSS)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert.vde.com/en/advisories/VDE-2022-004/",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
              }
            ],
            "source": {
              "advisory": "VDE-2022-004",
              "defect": [
                "CERT@VDE#64068"
              ],
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-22511",
        "datePublished": "2022-03-09T19:38:43.516Z",
        "dateReserved": "2022-01-03T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:16:00.059Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }