Search

Find a vulnerability

Search criteria

    8 vulnerabilities found for 750-363_firmware by wago

    CVE-2023-1150 (GCVE-0-2023-1150)

    Vulnerability from nvd – Published: 2023-06-26 06:19 – Updated: 2024-12-05 19:07
    VLAI
    Title
    WAGO: Series 750-3x/-8x prone to MODBUS server DoS
    Summary
    Uncontrolled resource consumption in Series WAGO 750-3x/-8x products may allow an unauthenticated remote attacker to DoS the MODBUS server with specially crafted packets.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-772 - Missing Release of Resource after Effective Lifetime
    Assigner
    References
    Impacted products
    Credits
    Roman Ezhov from Kaspersky
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:40:57.941Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-005/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-1150",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-05T19:06:44.632463Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-05T19:07:34.007Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "750-332",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-362/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-363/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-364/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-365/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-823",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-832/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-862",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-890/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-891",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-893",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Roman Ezhov from Kaspersky"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Uncontrolled resource consumption in Series WAGO 750-3x/-8x products may allow an unauthenticated remote attacker to DoS the MODBUS server with specially crafted packets."
                }
              ],
              "value": "Uncontrolled resource consumption in Series WAGO 750-3x/-8x products may allow an unauthenticated remote attacker to DoS the MODBUS server with specially crafted packets."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-772",
                  "description": "CWE-772 Missing Release of Resource after Effective Lifetime",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-02T05:26:51.589Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-005/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-005",
            "defect": [
              "CERT@VDE#64392"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "WAGO: Series 750-3x/-8x prone to MODBUS server DoS",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-1150",
        "datePublished": "2023-06-26T06:19:53.942Z",
        "dateReserved": "2023-03-02T05:38:38.812Z",
        "dateUpdated": "2024-12-05T19:07:34.007Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34578 (GCVE-0-2021-34578)

    Vulnerability from nvd – Published: 2021-08-31 10:33 – Updated: 2024-09-16 18:33
    VLAI
    Title
    WAGO: Authentication Vulnerability in Web-Based Management
    Summary
    This vulnerability allows an attacker who has access to the WBM to read and write settings-parameters of the device by sending specifically constructed requests without authentication on multiple WAGO PLCs in firmware versions up to FW07.
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO PLC Affected: 750-362 , ≤ FW07 (custom)
    Affected: 750-363 , ≤ FW07 (custom)
    Affected: 750-823 , ≤ FW07 (custom)
    Affected: 750-832/xxx-xxx , ≤ FW07 (custom)
    Affected: 750-862 , ≤ FW07 (custom)
    Affected: 750-891 , ≤ FW07 (custom)
    Affected: 750-890/xxx-xxx , ≤ FW07 (custom)
    Affected: 750-893 , ≤ FW07 (custom)
    Create a notification for this product.
    Date Public
    2021-08-31 00:00
    Credits
    Maxim Rupp (https://rupp.it) reported this vulnerability to WAGO. CERT@VDE coordinated.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:19:47.008Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en-us/advisories/vde-2020-044"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "PLC",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-362",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-363",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-823",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-832/xxx-xxx",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-862",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-891",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-890/xxx-xxx",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-893",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Maxim Rupp (https://rupp.it) reported this vulnerability to WAGO. CERT@VDE coordinated."
            }
          ],
          "datePublic": "2021-08-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "This vulnerability allows an attacker who has access to the WBM to read and write settings-parameters of the device by sending specifically constructed requests without authentication on multiple WAGO PLCs in firmware versions up to FW07."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-31T10:33:01.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en-us/advisories/vde-2020-044"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update the device to the latest FW version."
            }
          ],
          "source": {
            "advisory": "VDE-2020-044",
            "discovery": "EXTERNAL"
          },
          "title": "WAGO: Authentication Vulnerability in Web-Based Management",
          "workarounds": [
            {
              "lang": "en",
              "value": "Restrict network access to the device.\nDo not directly connect the device to the internet.\nDisable unused TCP/UDP ports.\nDisable web-based management ports 80/443 after the configuration phase"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2021-08-31T07:00:00.000Z",
              "ID": "CVE-2021-34578",
              "STATE": "PUBLIC",
              "TITLE": "WAGO: Authentication Vulnerability in Web-Based Management"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "PLC",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-362",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-363",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-823",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-832/xxx-xxx",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-862",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-891",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-890/xxx-xxx",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-893",
                                "version_value": "FW07"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "WAGO"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Maxim Rupp (https://rupp.it) reported this vulnerability to WAGO. CERT@VDE coordinated."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "This vulnerability allows an attacker who has access to the WBM to read and write settings-parameters of the device by sending specifically constructed requests without authentication on multiple WAGO PLCs in firmware versions up to FW07."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-287 Improper Authentication"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert.vde.com/en-us/advisories/vde-2020-044",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en-us/advisories/vde-2020-044"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update the device to the latest FW version."
              }
            ],
            "source": {
              "advisory": "VDE-2020-044",
              "discovery": "EXTERNAL"
            },
            "work_around": [
              {
                "lang": "en",
                "value": "Restrict network access to the device.\nDo not directly connect the device to the internet.\nDisable unused TCP/UDP ports.\nDisable web-based management ports 80/443 after the configuration phase"
              }
            ]
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34578",
        "datePublished": "2021-08-31T10:33:01.868Z",
        "dateReserved": "2021-06-10T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:33:25.112Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-12506 (GCVE-0-2020-12506)

    Vulnerability from nvd – Published: 2020-09-30 15:43 – Updated: 2024-09-17 00:06
    VLAI
    Title
    WAGO: Authentication Bypass Vulnerability in WAGO 750-36X and WAGO 750-8XX Versions <= FW03
    Summary
    Improper Authentication vulnerability in WAGO 750-8XX series with FW version <= FW03 allows an attacker to change the settings of the devices by sending specifically constructed requests without authentication This issue affects: WAGO 750-362, WAGO 750-363, WAGO 750-823, WAGO 750-832/xxx-xxx, WAGO 750-862, WAGO 750-891, WAGO 750-890/xxx-xxx in versions FW03 and prior versions.
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-362 Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    WAGO 750-363 Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    WAGO 750-823 Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    WAGO 750-832/xxx-xxx Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    WAGO 750-862 Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    WAGO 750-891 Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    WAGO 750-890/xxx-xxx Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    Date Public
    2020-09-29 00:00
    Credits
    Maxim Rupp (https://rupp.it) reported this vulnerability to WAGO. coordinated by CERT@VDE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:56:52.087Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en-us/advisories/vde-2020-028"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "750-362",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-363",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-823",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-832/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-862",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-891",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-890/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Maxim Rupp (https://rupp.it) reported this vulnerability to WAGO."
            },
            {
              "lang": "en",
              "value": "coordinated by CERT@VDE"
            }
          ],
          "datePublic": "2020-09-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper Authentication vulnerability in WAGO 750-8XX series with FW version \u003c= FW03 allows an attacker to change the settings of the devices by sending specifically constructed requests without authentication This issue affects: WAGO 750-362, WAGO 750-363, WAGO 750-823, WAGO 750-832/xxx-xxx, WAGO 750-862, WAGO 750-891, WAGO 750-890/xxx-xxx in versions FW03 and prior versions."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-11-10T11:22:01.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en-us/advisories/vde-2020-028"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Upgrade devices to the latest standard firmware (\u003e FW03)."
            }
          ],
          "source": {
            "advisory": "vde-2020-028",
            "defect": [
              "vde-2020-028"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "WAGO: Authentication Bypass Vulnerability in WAGO 750-36X and WAGO 750-8XX Versions \u003c= FW03",
          "workarounds": [
            {
              "lang": "en",
              "value": "Restrict network access to the device.\nDo not directly connect the device to the internet.\nDisable unused TCP/UDP ports.\nDisable web-based management ports 80/443 after the configuration phase"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2020-09-29T22:00:00.000Z",
              "ID": "CVE-2020-12506",
              "STATE": "PUBLIC",
              "TITLE": "WAGO: Authentication Bypass Vulnerability in WAGO 750-36X and WAGO 750-8XX Versions \u003c= FW03"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "750-362",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "750-363",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "750-823",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "750-832/xxx-xxx",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "750-862",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "750-891",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "750-890/xxx-xxx",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "WAGO"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Maxim Rupp (https://rupp.it) reported this vulnerability to WAGO."
              },
              {
                "lang": "eng",
                "value": "coordinated by CERT@VDE"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper Authentication vulnerability in WAGO 750-8XX series with FW version \u003c= FW03 allows an attacker to change the settings of the devices by sending specifically constructed requests without authentication This issue affects: WAGO 750-362, WAGO 750-363, WAGO 750-823, WAGO 750-832/xxx-xxx, WAGO 750-862, WAGO 750-891, WAGO 750-890/xxx-xxx in versions FW03 and prior versions."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-306 Missing Authentication for Critical Function"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert.vde.com/en-us/advisories/vde-2020-028",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en-us/advisories/vde-2020-028"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Upgrade devices to the latest standard firmware (\u003e FW03)."
              }
            ],
            "source": {
              "advisory": "vde-2020-028",
              "defect": [
                "vde-2020-028"
              ],
              "discovery": "EXTERNAL"
            },
            "work_around": [
              {
                "lang": "en",
                "value": "Restrict network access to the device.\nDo not directly connect the device to the internet.\nDisable unused TCP/UDP ports.\nDisable web-based management ports 80/443 after the configuration phase"
              }
            ]
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2020-12506",
        "datePublished": "2020-09-30T15:43:20.405Z",
        "dateReserved": "2020-04-30T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:06:46.518Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-16210 (GCVE-0-2018-16210)

    Vulnerability from nvd – Published: 2018-10-12 20:00 – Updated: 2024-08-05 10:17
    VLAI
    Summary
    WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    https://www.exploit-db.com/exploits/45581/ exploitx_refsource_EXPLOIT-DB
    Date Public
    2018-10-11 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T10:17:38.400Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "45581",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/45581/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-10-11T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-05-13T12:17:05.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "45581",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/45581/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-16210",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "45581",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/45581/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-16210",
        "datePublished": "2018-10-12T20:00:00.000Z",
        "dateReserved": "2018-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T10:17:38.400Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2023-1150 (GCVE-0-2023-1150)

    Vulnerability from cvelistv5 – Published: 2023-06-26 06:19 – Updated: 2024-12-05 19:07
    VLAI
    Title
    WAGO: Series 750-3x/-8x prone to MODBUS server DoS
    Summary
    Uncontrolled resource consumption in Series WAGO 750-3x/-8x products may allow an unauthenticated remote attacker to DoS the MODBUS server with specially crafted packets.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-772 - Missing Release of Resource after Effective Lifetime
    Assigner
    References
    Impacted products
    Credits
    Roman Ezhov from Kaspersky
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T05:40:57.941Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2023-005/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-1150",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-12-05T19:06:44.632463Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-12-05T19:07:34.007Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "750-332",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-362/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-363/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-364/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-365/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-823",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-832/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-862",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-890/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-891",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "750-893",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW10",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Roman Ezhov from Kaspersky"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Uncontrolled resource consumption in Series WAGO 750-3x/-8x products may allow an unauthenticated remote attacker to DoS the MODBUS server with specially crafted packets."
                }
              ],
              "value": "Uncontrolled resource consumption in Series WAGO 750-3x/-8x products may allow an unauthenticated remote attacker to DoS the MODBUS server with specially crafted packets."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-772",
                  "description": "CWE-772 Missing Release of Resource after Effective Lifetime",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-02T05:26:51.589Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2023-005/"
            }
          ],
          "source": {
            "advisory": "VDE-2023-005",
            "defect": [
              "CERT@VDE#64392"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "WAGO: Series 750-3x/-8x prone to MODBUS server DoS",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2023-1150",
        "datePublished": "2023-06-26T06:19:53.942Z",
        "dateReserved": "2023-03-02T05:38:38.812Z",
        "dateUpdated": "2024-12-05T19:07:34.007Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-34578 (GCVE-0-2021-34578)

    Vulnerability from cvelistv5 – Published: 2021-08-31 10:33 – Updated: 2024-09-16 18:33
    VLAI
    Title
    WAGO: Authentication Vulnerability in Web-Based Management
    Summary
    This vulnerability allows an attacker who has access to the WBM to read and write settings-parameters of the device by sending specifically constructed requests without authentication on multiple WAGO PLCs in firmware versions up to FW07.
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO PLC Affected: 750-362 , ≤ FW07 (custom)
    Affected: 750-363 , ≤ FW07 (custom)
    Affected: 750-823 , ≤ FW07 (custom)
    Affected: 750-832/xxx-xxx , ≤ FW07 (custom)
    Affected: 750-862 , ≤ FW07 (custom)
    Affected: 750-891 , ≤ FW07 (custom)
    Affected: 750-890/xxx-xxx , ≤ FW07 (custom)
    Affected: 750-893 , ≤ FW07 (custom)
    Create a notification for this product.
    Date Public
    2021-08-31 00:00
    Credits
    Maxim Rupp (https://rupp.it) reported this vulnerability to WAGO. CERT@VDE coordinated.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T00:19:47.008Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en-us/advisories/vde-2020-044"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "PLC",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-362",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-363",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-823",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-832/xxx-xxx",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-862",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-891",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-890/xxx-xxx",
                  "versionType": "custom"
                },
                {
                  "lessThanOrEqual": "FW07",
                  "status": "affected",
                  "version": "750-893",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Maxim Rupp (https://rupp.it) reported this vulnerability to WAGO. CERT@VDE coordinated."
            }
          ],
          "datePublic": "2021-08-31T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "This vulnerability allows an attacker who has access to the WBM to read and write settings-parameters of the device by sending specifically constructed requests without authentication on multiple WAGO PLCs in firmware versions up to FW07."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287 Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-08-31T10:33:01.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en-us/advisories/vde-2020-044"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update the device to the latest FW version."
            }
          ],
          "source": {
            "advisory": "VDE-2020-044",
            "discovery": "EXTERNAL"
          },
          "title": "WAGO: Authentication Vulnerability in Web-Based Management",
          "workarounds": [
            {
              "lang": "en",
              "value": "Restrict network access to the device.\nDo not directly connect the device to the internet.\nDisable unused TCP/UDP ports.\nDisable web-based management ports 80/443 after the configuration phase"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2021-08-31T07:00:00.000Z",
              "ID": "CVE-2021-34578",
              "STATE": "PUBLIC",
              "TITLE": "WAGO: Authentication Vulnerability in Web-Based Management"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "PLC",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-362",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-363",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-823",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-832/xxx-xxx",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-862",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-891",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-890/xxx-xxx",
                                "version_value": "FW07"
                              },
                              {
                                "version_affected": "\u003c=",
                                "version_name": "750-893",
                                "version_value": "FW07"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "WAGO"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Maxim Rupp (https://rupp.it) reported this vulnerability to WAGO. CERT@VDE coordinated."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "This vulnerability allows an attacker who has access to the WBM to read and write settings-parameters of the device by sending specifically constructed requests without authentication on multiple WAGO PLCs in firmware versions up to FW07."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-287 Improper Authentication"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert.vde.com/en-us/advisories/vde-2020-044",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en-us/advisories/vde-2020-044"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update the device to the latest FW version."
              }
            ],
            "source": {
              "advisory": "VDE-2020-044",
              "discovery": "EXTERNAL"
            },
            "work_around": [
              {
                "lang": "en",
                "value": "Restrict network access to the device.\nDo not directly connect the device to the internet.\nDisable unused TCP/UDP ports.\nDisable web-based management ports 80/443 after the configuration phase"
              }
            ]
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2021-34578",
        "datePublished": "2021-08-31T10:33:01.868Z",
        "dateReserved": "2021-06-10T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:33:25.112Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-12506 (GCVE-0-2020-12506)

    Vulnerability from cvelistv5 – Published: 2020-09-30 15:43 – Updated: 2024-09-17 00:06
    VLAI
    Title
    WAGO: Authentication Bypass Vulnerability in WAGO 750-36X and WAGO 750-8XX Versions <= FW03
    Summary
    Improper Authentication vulnerability in WAGO 750-8XX series with FW version <= FW03 allows an attacker to change the settings of the devices by sending specifically constructed requests without authentication This issue affects: WAGO 750-362, WAGO 750-363, WAGO 750-823, WAGO 750-832/xxx-xxx, WAGO 750-862, WAGO 750-891, WAGO 750-890/xxx-xxx in versions FW03 and prior versions.
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-362 Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    WAGO 750-363 Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    WAGO 750-823 Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    WAGO 750-832/xxx-xxx Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    WAGO 750-862 Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    WAGO 750-891 Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    WAGO 750-890/xxx-xxx Affected: unspecified , ≤ FW03 (custom)
    Create a notification for this product.
    Date Public
    2020-09-29 00:00
    Credits
    Maxim Rupp (https://rupp.it) reported this vulnerability to WAGO. coordinated by CERT@VDE
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:56:52.087Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en-us/advisories/vde-2020-028"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "750-362",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-363",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-823",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-832/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-862",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-891",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-890/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "FW03",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Maxim Rupp (https://rupp.it) reported this vulnerability to WAGO."
            },
            {
              "lang": "en",
              "value": "coordinated by CERT@VDE"
            }
          ],
          "datePublic": "2020-09-29T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper Authentication vulnerability in WAGO 750-8XX series with FW version \u003c= FW03 allows an attacker to change the settings of the devices by sending specifically constructed requests without authentication This issue affects: WAGO 750-362, WAGO 750-363, WAGO 750-823, WAGO 750-832/xxx-xxx, WAGO 750-862, WAGO 750-891, WAGO 750-890/xxx-xxx in versions FW03 and prior versions."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-11-10T11:22:01.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en-us/advisories/vde-2020-028"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Upgrade devices to the latest standard firmware (\u003e FW03)."
            }
          ],
          "source": {
            "advisory": "vde-2020-028",
            "defect": [
              "vde-2020-028"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "WAGO: Authentication Bypass Vulnerability in WAGO 750-36X and WAGO 750-8XX Versions \u003c= FW03",
          "workarounds": [
            {
              "lang": "en",
              "value": "Restrict network access to the device.\nDo not directly connect the device to the internet.\nDisable unused TCP/UDP ports.\nDisable web-based management ports 80/443 after the configuration phase"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2020-09-29T22:00:00.000Z",
              "ID": "CVE-2020-12506",
              "STATE": "PUBLIC",
              "TITLE": "WAGO: Authentication Bypass Vulnerability in WAGO 750-36X and WAGO 750-8XX Versions \u003c= FW03"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "750-362",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "750-363",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "750-823",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "750-832/xxx-xxx",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "750-862",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "750-891",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "750-890/xxx-xxx",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c=",
                                "version_value": "FW03"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "WAGO"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Maxim Rupp (https://rupp.it) reported this vulnerability to WAGO."
              },
              {
                "lang": "eng",
                "value": "coordinated by CERT@VDE"
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper Authentication vulnerability in WAGO 750-8XX series with FW version \u003c= FW03 allows an attacker to change the settings of the devices by sending specifically constructed requests without authentication This issue affects: WAGO 750-362, WAGO 750-363, WAGO 750-823, WAGO 750-832/xxx-xxx, WAGO 750-862, WAGO 750-891, WAGO 750-890/xxx-xxx in versions FW03 and prior versions."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-306 Missing Authentication for Critical Function"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert.vde.com/en-us/advisories/vde-2020-028",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en-us/advisories/vde-2020-028"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Upgrade devices to the latest standard firmware (\u003e FW03)."
              }
            ],
            "source": {
              "advisory": "vde-2020-028",
              "defect": [
                "vde-2020-028"
              ],
              "discovery": "EXTERNAL"
            },
            "work_around": [
              {
                "lang": "en",
                "value": "Restrict network access to the device.\nDo not directly connect the device to the internet.\nDisable unused TCP/UDP ports.\nDisable web-based management ports 80/443 after the configuration phase"
              }
            ]
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2020-12506",
        "datePublished": "2020-09-30T15:43:20.405Z",
        "dateReserved": "2020-04-30T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:06:46.518Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-16210 (GCVE-0-2018-16210)

    Vulnerability from cvelistv5 – Published: 2018-10-12 20:00 – Updated: 2024-08-05 10:17
    VLAI
    Summary
    WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    URL Tags
    https://www.exploit-db.com/exploits/45581/ exploitx_refsource_EXPLOIT-DB
    Date Public
    2018-10-11 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T10:17:38.400Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "45581",
                "tags": [
                  "exploit",
                  "x_refsource_EXPLOIT-DB",
                  "x_transferred"
                ],
                "url": "https://www.exploit-db.com/exploits/45581/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-10-11T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-05-13T12:17:05.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "name": "45581",
              "tags": [
                "exploit",
                "x_refsource_EXPLOIT-DB"
              ],
              "url": "https://www.exploit-db.com/exploits/45581/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-16210",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "WAGO 750-88X and WAGO 750-89X Ethernet Controller devices, versions 01.09.18(13) and before, have XSS in the SNMP configuration via the webserv/cplcfg/snmp.ssi SNMP_DESC or SNMP_LOC_SNMP_CONT field."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "45581",
                  "refsource": "EXPLOIT-DB",
                  "url": "https://www.exploit-db.com/exploits/45581/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-16210",
        "datePublished": "2018-10-12T20:00:00.000Z",
        "dateReserved": "2018-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T10:17:38.400Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }