<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://db.gcve.eu</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Thu, 01 Oct 2026 23:57:03 +0000</lastBuildDate>
    <item>
      <title>CVE-2023-1256 — CVE-2023-1256</title>
      <link>https://db.gcve.eu/vuln/cve-2023-1256</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; AVEVA Plant SCADA, AVEVA Telemetry Server&lt;/p&gt;
&lt;p&gt;The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; AVEVA Plant SCADA, AVEVA Telemetry Server&lt;/p&gt;
&lt;p&gt;The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit which could allow an unauthenticated user to remotely read data, cause denial of service, and tamper with alarm states.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://db.gcve.eu/vuln/cve-2023-1256</guid>
    </item>
    <item>
      <title>ICSA-23-073-04 — AVEVA Plant SCADA and AVEVA Telemetry Server</title>
      <link>https://db.gcve.eu/vuln/icsa-23-073-04</link>
      <description>&lt;p&gt;The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit, which could allow an unauthenticated user to remotely read data, cause a denial-of-service condition, and tamper with alarm states. CVE-2023-1256 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The listed versions of AVEVA Plant SCADA and AVEVA Telemetry Server are vulnerable to an improper authorization exploit, which could allow an unauthenticated user to remotely read data, cause a denial-of-service condition, and tamper with alarm states. CVE-2023-1256 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://db.gcve.eu/vuln/icsa-23-073-04</guid>
    </item>
  </channel>
</rss>
