<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://db.gcve.eu</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Sat, 03 Oct 2026 05:58:53 +0000</lastBuildDate>
    <item>
      <title>bdu:2024-05963</title>
      <link>https://db.gcve.eu/vuln/bdu:2024-05963</link>
      <description>bdu:2024-05963</description>
      <guid isPermaLink="false">https://db.gcve.eu/vuln/bdu:2024-05963</guid>
    </item>
    <item>
      <title>CVE-2024-6242 — Rockwell Automation Chassis Restrictions Bypass Vulnerability in Select Logix Devices</title>
      <link>https://db.gcve.eu/vuln/cve-2024-6242</link>
      <description>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Rockwell Automation ControlLogix® 5580 (1756-L8z), Rockwell Automation GuardLogix® 5580  (1756-L8zS), Rockwell Automation 1756-EN4TR, Rockwell Automation 1756-EN2T, Rockwell Automation 1756-EN2F, Rockwell Automation 1756-EN2TR, Rockwell Automation 1756-EN3TR, Rockwell Automation 1756-EN2TP&lt;/p&gt;
&lt;p&gt;A vulnerability exists in Rockwell Automation affected products that allows a threat actor to bypass the Trusted® Slot feature in a ControlLogix® controller. If exploited on any affected module in a 1756 chassis, a threat actor could potentially execute CIP commands that modify user projects and/or device configuration on a Logix controller in the chassis.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;&lt;strong&gt;Affected:&lt;/strong&gt; Rockwell Automation ControlLogix® 5580 (1756-L8z), Rockwell Automation GuardLogix® 5580  (1756-L8zS), Rockwell Automation 1756-EN4TR, Rockwell Automation 1756-EN2T, Rockwell Automation 1756-EN2F, Rockwell Automation 1756-EN2TR, Rockwell Automation 1756-EN3TR, Rockwell Automation 1756-EN2TP&lt;/p&gt;
&lt;p&gt;A vulnerability exists in Rockwell Automation affected products that allows a threat actor to bypass the Trusted® Slot feature in a ControlLogix® controller. If exploited on any affected module in a 1756 chassis, a threat actor could potentially execute CIP commands that modify user projects and/or device configuration on a Logix controller in the chassis.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://db.gcve.eu/vuln/cve-2024-6242</guid>
    </item>
  </channel>
</rss>
