      <title>fkie_cve-2026-79976</title>
      <link>https://db.gcve.eu/vuln/fkie_cve-2026-79976</link>
      <description>&lt;p&gt;The MCTP-over-I2C+GPIO target binding in subsys/pmci/mctp/mctp_i2c_gpio_target.c emulates a small pseudo-register file, where the bus controller first writes a register number and then writes or reads payload bytes. The selected register (b-&amp;gt;reg_addr) and the data-phase flag (b-&amp;gt;rxtx) were never cleared when the controller issued an I2C STOP, so after a completed transfer the target still had a data register selected while the packet buffer that register refers to had already been consumed and set to NULL by mctp_i2c_gpio_target_stop().&lt;/p&gt;
&lt;p&gt;A controller on the bus can re-enter the same branch of mctp_i2c_gpio_target_stop() with a NULL buffer using two ordinary transactions and no authentication: first a normal packet write to MCTP_I2C_GPIO_RX_MSG_ADDR followed by STOP (which delivers and frees b-&amp;gt;rx_pkt), then a bare read transaction followed by STOP. The failing read_requested() call leaves the stale state untouched and the I2C driver still delivers the STOP callback, which then calls mctp_bus_rx() with a NULL packet. The symmetric case exists on the transmit side, where the stale MCTP_I2C_GPIO_TX_MSG_ADDR selection dereferences b-&amp;gt;tx_pkt-&amp;gt;end after b-&amp;gt;tx_pkt has been cleared and additionally signals b-&amp;gt;tx_complete a second time, causing the next outbound packet to be dropped.&lt;/p&gt;
&lt;p&gt;The dereference happens in the I2C target interrupt handler, so on any target that traps accesses to address 0 the result is a fatal exception and a device reset or halt — a denial of service inflicted…&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;The MCTP-over-I2C+GPIO target binding in subsys/pmci/mctp/mctp_i2c_gpio_target.c emulates a small pseudo-register file, where the bus controller first writes a register number and then writes or reads payload bytes. The selected register (b-&amp;gt;reg_addr) and the data-phase flag (b-&amp;gt;rxtx) were never cleared when the controller issued an I2C STOP, so after a completed transfer the target still had a data register selected while the packet buffer that register refers to had already been consumed and set to NULL by mctp_i2c_gpio_target_stop().&lt;/p&gt;
&lt;p&gt;A controller on the bus can re-enter the same branch of mctp_i2c_gpio_target_stop() with a NULL buffer using two ordinary transactions and no authentication: first a normal packet write to MCTP_I2C_GPIO_RX_MSG_ADDR followed by STOP (which delivers and frees b-&amp;gt;rx_pkt), then a bare read transaction followed by STOP. The failing read_requested() call leaves the stale state untouched and the I2C driver still delivers the STOP callback, which then calls mctp_bus_rx() with a NULL packet. The symmetric case exists on the transmit side, where the stale MCTP_I2C_GPIO_TX_MSG_ADDR selection dereferences b-&amp;gt;tx_pkt-&amp;gt;end after b-&amp;gt;tx_pkt has been cleared and additionally signals b-&amp;gt;tx_complete a second time, causing the next outbound packet to be dropped.&lt;/p&gt;
&lt;p&gt;The dereference happens in the I2C target interrupt handler, so on any target that traps accesses to address 0 the result is a fatal exception and a device reset or halt — a denial of service inflicted…&lt;/p&gt;</content:encoded>