<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/" version="2.0">
  <channel>
    <title>Most recent entries from all</title>
    <link>https://db.gcve.eu</link>
    <description>Contains only the most 10 recent entries.</description>
    <docs>http://www.rssboard.org/rss-specification</docs>
    <generator>python-feedgen</generator>
    <language>en</language>
    <lastBuildDate>Fri, 06 Nov 2026 23:50:59 +0000</lastBuildDate>
    <item>
      <title>fkie_cve-2026-120749</title>
      <link>https://db.gcve.eu/vuln/fkie_cve-2026-120749</link>
      <description>&lt;p&gt;A flaw was found in D-Bus. With a privileged Monitoring client attached (for example dbus-monitor or busctl monitor), an unprivileged local user can cause dbus-daemon to abort if a driver-originated broadcast such as NameOwnerChanged or ActivatableServicesChanged cannot be delivered to a recipient (for example due to a deny rule or an exceeded outgoing message queue). Driver broadcasts still use serial 0; when delivery fails, composing the monitor error reply asserts reply_serial != 0 and aborts the daemon. This is an incomplete fix for CVE-2023-34969, which only assigned serials for driver messages sent to a single recipient. On the well-known system bus this is a denial of service.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A flaw was found in D-Bus. With a privileged Monitoring client attached (for example dbus-monitor or busctl monitor), an unprivileged local user can cause dbus-daemon to abort if a driver-originated broadcast such as NameOwnerChanged or ActivatableServicesChanged cannot be delivered to a recipient (for example due to a deny rule or an exceeded outgoing message queue). Driver broadcasts still use serial 0; when delivery fails, composing the monitor error reply asserts reply_serial != 0 and aborts the daemon. This is an incomplete fix for CVE-2023-34969, which only assigned serials for driver messages sent to a single recipient. On the well-known system bus this is a denial of service.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://db.gcve.eu/vuln/fkie_cve-2026-120749</guid>
    </item>
    <item>
      <title>GHSA-r7wg-4x32-8p6v</title>
      <link>https://db.gcve.eu/vuln/ghsa-r7wg-4x32-8p6v</link>
      <description>&lt;p&gt;A flaw was found in D-Bus. With a privileged Monitoring client attached (for example dbus-monitor or busctl monitor), an unprivileged local user can cause dbus-daemon to abort if a driver-originated broadcast such as NameOwnerChanged or ActivatableServicesChanged cannot be delivered to a recipient (for example due to a deny rule or an exceeded outgoing message queue). Driver broadcasts still use serial 0; when delivery fails, composing the monitor error reply asserts reply_serial != 0 and aborts the daemon. This is an incomplete fix for CVE-2023-34969, which only assigned serials for driver messages sent to a single recipient. On the well-known system bus this is a denial of service.&lt;/p&gt;</description>
      <content:encoded>&lt;p&gt;A flaw was found in D-Bus. With a privileged Monitoring client attached (for example dbus-monitor or busctl monitor), an unprivileged local user can cause dbus-daemon to abort if a driver-originated broadcast such as NameOwnerChanged or ActivatableServicesChanged cannot be delivered to a recipient (for example due to a deny rule or an exceeded outgoing message queue). Driver broadcasts still use serial 0; when delivery fails, composing the monitor error reply asserts reply_serial != 0 and aborts the daemon. This is an incomplete fix for CVE-2023-34969, which only assigned serials for driver messages sent to a single recipient. On the well-known system bus this is a denial of service.&lt;/p&gt;</content:encoded>
      <guid isPermaLink="false">https://db.gcve.eu/vuln/ghsa-r7wg-4x32-8p6v</guid>
    </item>
  </channel>
</rss>
