  <entry>
    <id>https://db.gcve.eu/vuln/fkie_cve-2026-99022</id>
    <title>fkie_cve-2026-99022</title>
    <updated>2026-10-24T22:13:53.395648+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>In the Linux kernel, the following vulnerability has been resolved:</p>
<p>regulator: ltc3676: don't read the write-only HRST and CLIRQ registers</p>
<p>HRST (0x1e) and CLIRQ (0x1f) are write-only command strobes. Writing HRST
triggers a hard reset of the chip and writing CLIRQ clears the interrupt;
reading them returns nothing useful, and the read itself fires the command.</p>
<p>The result is that a plain register dump resets the board:</p>
<p>cat /sys/kernel/debug/regmap/2-003c/registers</p>
<p>walks every readable register, hits HRST, and the board reboots.</p>
<p>Split the callback back in two so HRST and CLIRQ stay writable but are no
longer readable. The readable range is left unchanged
(LTC3676_BUCK1 ... LTC3676_IRQSTAT).</p></div>
    </content>
    <link href="https://db.gcve.eu/vuln/fkie_cve-2026-99022"/>
  </entry>
  <entry>
    <id>https://db.gcve.eu/vuln/ghsa-668q-74cv-frqc</id>
    <title>GHSA-668q-74cv-frqc</title>
    <updated>2026-10-24T22:13:53.395733+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>In the Linux kernel, the following vulnerability has been resolved:</p>
<p>regulator: ltc3676: don't read the write-only HRST and CLIRQ registers</p>
<p>HRST (0x1e) and CLIRQ (0x1f) are write-only command strobes. Writing HRST
triggers a hard reset of the chip and writing CLIRQ clears the interrupt;
reading them returns nothing useful, and the read itself fires the command.</p>
<p>The result is that a plain register dump resets the board:</p>
<p>cat /sys/kernel/debug/regmap/2-003c/registers</p>
<p>walks every readable register, hits HRST, and the board reboots.</p>
<p>Split the callback back in two so HRST and CLIRQ stay writable but are no
longer readable. The readable range is left unchanged
(LTC3676_BUCK1 ... LTC3676_IRQSTAT).</p></div>