<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://db.gcve.eu/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-09-30T19:19:42.197447+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>info@gcve.eu</email>
  </author>
  <link href="https://db.gcve.eu" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://db.gcve.eu/vuln/cve-2025-41709</id>
    <title>CVE-2025-41709 — Command injection in power analyzer via Modbus-TCP and Modbus-RTU</title>
    <updated>2026-09-30T19:19:42.210068+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p><strong>Affected:</strong> Janitza UMG 96RM-E 24V(5222063), Janitza UMG 96RM-E 230V(5222062), Weidmueller ENERGY METER 750-230 (2540910000), Weidmueller ENERGY METER 750-24 (2540900000)</p>
<p>An unauthenticated remote attacker can perform a command injection via Modbus-TCP or Modbus-RTU to gain read and write access on the affected device.</p></div>
    </content>
    <link href="https://db.gcve.eu/vuln/cve-2025-41709"/>
  </entry>
  <entry>
    <id>https://db.gcve.eu/vuln/vde-2025-079</id>
    <title>VDE-2025-079 — Janitza: Multiple vulnerabilities in UMG 96RM-E</title>
    <updated>2026-09-30T19:19:42.210148+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An unauthenticated remote attacker can exploit several vulnerabilities in Janitza UMG 96RM-E devices to ultimately gain full system access and remote code execution.</p>
      </div>
    </content>
    <link href="https://db.gcve.eu/vuln/vde-2025-079"/>
  </entry>
  <entry>
    <id>https://db.gcve.eu/vuln/vde-2025-096</id>
    <title>VDE-2025-096 — Weidmueller: Multiple vulnerabilities in Energy Meter 750-24 and Energy Meter 750-230</title>
    <updated>2026-09-30T19:19:42.210179+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>An unauthenticated remote attacker can exploit several vulnerabilities in Weidmueller devices Energy Meter 750-24 and Energy Meter 750-230 to ultimately gain full system access and remote code execution.</p>
      </div>
    </content>
    <link href="https://db.gcve.eu/vuln/vde-2025-096"/>
  </entry>