<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://db.gcve.eu/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-11-03T12:06:58.325927+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>info@gcve.eu</email>
  </author>
  <link href="https://db.gcve.eu" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://db.gcve.eu/vuln/fkie_cve-2026-98676</id>
    <title>fkie_cve-2026-98676</title>
    <updated>2026-11-03T12:06:58.362089+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>In the Linux kernel, the following vulnerability has been resolved:</p>
<p>iio: adc: ade9000: fix NULL pointer dereference in clkout registration</p>
<p>ade9000_setup_clkout() passes NULL as the register address when
registering a divider clock. During clock registration, the common
clock framework calls clk_divider_recalc_rate(), which dereferences
the address through readl(). As a result, probing an ADE9000 configured
as a clock provider with an external input clock crashes.</p>
<p>CLKOUT passes CLKIN through without changing its rate. Register it as
a 1:1 fixed-factor clock, which does not require register access.</p>
<p>This change does not affect the configuration using the internal clock,
for which the driver does not register a clock provider.</p></div>
    </content>
    <link href="https://db.gcve.eu/vuln/fkie_cve-2026-98676"/>
  </entry>
  <entry>
    <id>https://db.gcve.eu/vuln/ghsa-qchf-h949-mmvh</id>
    <title>GHSA-qchf-h949-mmvh</title>
    <updated>2026-11-03T12:06:58.362176+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p>In the Linux kernel, the following vulnerability has been resolved:</p>
<p>iio: adc: ade9000: fix NULL pointer dereference in clkout registration</p>
<p>ade9000_setup_clkout() passes NULL as the register address when
registering a divider clock. During clock registration, the common
clock framework calls clk_divider_recalc_rate(), which dereferences
the address through readl(). As a result, probing an ADE9000 configured
as a clock provider with an external input clock crashes.</p>
<p>CLKOUT passes CLKIN through without changing its rate. Register it as
a 1:1 fixed-factor clock, which does not require register access.</p>
<p>This change does not affect the configuration using the internal clock,
for which the driver does not register a clock provider.</p></div>
    </content>
    <link href="https://db.gcve.eu/vuln/ghsa-qchf-h949-mmvh"/>
  </entry>
  <entry>
    <id>https://db.gcve.eu/vuln/msrc_cve-2026-98676</id>
    <title>msrc_CVE-2026-98676 — iio: adc: ade9000: fix NULL pointer dereference in clkout registration</title>
    <updated>2026-11-03T12:06:58.362203+00:00</updated>
    <content>msrc_CVE-2026-98676</content>
    <link href="https://db.gcve.eu/vuln/msrc_cve-2026-98676"/>
  </entry>
  <entry>
    <id>https://db.gcve.eu/vuln/ubuntu-cve-2026-98676</id>
    <title>UBUNTU-CVE-2026-98676</title>
    <updated>2026-11-03T12:06:58.362226+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml"><p><strong>Affected:</strong> Ubuntu:16.04:LTS: linux-hwe-edge, Ubuntu:18.04:LTS: linux-aws-5.0, Ubuntu:18.04:LTS: linux-aws-5.3, Ubuntu:18.04:LTS: linux-azure, Ubuntu:18.04:LTS: linux-azure-5.3, Ubuntu:18.04:LTS: linux-azure-edge, Ubuntu:18.04:LTS: linux-gcp, Ubuntu:18.04:LTS: linux-gcp-5.3, Ubuntu:18.04:LTS: linux-gke-4.15, Ubuntu:18.04:LTS: linux-gke-5.4 and 118 more</p>
<p>In the Linux kernel, the following vulnerability has been resolved: iio: adc: ade9000: fix NULL pointer dereference in clkout registration ade9000_setup_clkout() passes NULL as the register address when registering a divider clock. During clock registration, the common clock framework calls clk_divider_recalc_rate(), which dereferences the address through readl(). As a result, probing an ADE9000 configured as a clock provider with an external input clock crashes. CLKOUT passes CLKIN through without changing its rate. Register it as a 1:1 fixed-factor clock, which does not require register access. This change does not affect the configuration using the internal clock, for which the driver does not register a clock provider.</p></div>
    </content>
    <link href="https://db.gcve.eu/vuln/ubuntu-cve-2026-98676"/>
  </entry>
  <entry>
    <id>https://db.gcve.eu/vuln/wid-sec-w-2026-4019</id>
    <title>WID-SEC-W-2026-4019 — Linux Kernel: Mehrere Schwachstellen</title>
    <updated>2026-11-03T12:06:58.362434+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>Ein Angreifer kann mehrere Schwachstellen im Linux Kernel ausnutzen, um einen nicht näher spezifizierten Angriff durchzuführen, möglicherweise einen Denial-of-Service-Angriff auszulösen, Daten zu manipulieren oder offenzulegen oder Sicherheitsmaßnahmen zu umgehen.</p>
      </div>
    </content>
    <link href="https://db.gcve.eu/vuln/wid-sec-w-2026-4019"/>
  </entry>
</feed>