<?xml version='1.0' encoding='UTF-8'?>
<?xml-stylesheet href="/static/style.xsl" type="text/xsl"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
  <id>https://db.gcve.eu/rss/recent/all/10</id>
  <title>Most recent entries from all</title>
  <updated>2026-11-06T23:50:57.313688+00:00</updated>
  <author>
    <name>Vulnerability-Lookup</name>
    <email>info@gcve.eu</email>
  </author>
  <link href="https://db.gcve.eu" rel="alternate"/>
  <generator uri="https://lkiesow.github.io/python-feedgen" version="1.0.0">python-feedgen</generator>
  <subtitle>Contains only the most 10 recent entries.</subtitle>
  <entry>
    <id>https://db.gcve.eu/vuln/fkie_cve-2026-120749</id>
    <title>fkie_cve-2026-120749</title>
    <updated>2026-11-06T23:50:57.324395+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A flaw was found in D-Bus. With a privileged Monitoring client attached (for example dbus-monitor or busctl monitor), an unprivileged local user can cause dbus-daemon to abort if a driver-originated broadcast such as NameOwnerChanged or ActivatableServicesChanged cannot be delivered to a recipient (for example due to a deny rule or an exceeded outgoing message queue). Driver broadcasts still use serial 0; when delivery fails, composing the monitor error reply asserts reply_serial != 0 and aborts the daemon. This is an incomplete fix for CVE-2023-34969, which only assigned serials for driver messages sent to a single recipient. On the well-known system bus this is a denial of service.</p>
      </div>
    </content>
    <link href="https://db.gcve.eu/vuln/fkie_cve-2026-120749"/>
  </entry>
  <entry>
    <id>https://db.gcve.eu/vuln/ghsa-r7wg-4x32-8p6v</id>
    <title>GHSA-r7wg-4x32-8p6v</title>
    <updated>2026-11-06T23:50:57.324457+00:00</updated>
    <content type="xhtml">
      <div xmlns="http://www.w3.org/1999/xhtml">
        <p>A flaw was found in D-Bus. With a privileged Monitoring client attached (for example dbus-monitor or busctl monitor), an unprivileged local user can cause dbus-daemon to abort if a driver-originated broadcast such as NameOwnerChanged or ActivatableServicesChanged cannot be delivered to a recipient (for example due to a deny rule or an exceeded outgoing message queue). Driver broadcasts still use serial 0; when delivery fails, composing the monitor error reply asserts reply_serial != 0 and aborts the daemon. This is an incomplete fix for CVE-2023-34969, which only assigned serials for driver messages sent to a single recipient. On the well-known system bus this is a denial of service.</p>
      </div>
    </content>
    <link href="https://db.gcve.eu/vuln/ghsa-r7wg-4x32-8p6v"/>
  </entry>
</feed>