CWE-269
Improper Privilege Management
The product does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.
CVE-2017-0932 (GCVE-0-2017-0932)
Vulnerability from cvelistv5 – Published: 2018-03-22 14:00 – Updated: 2024-09-17 02:27- CWE-269 - Improper Privilege Management (CWE-269)
| URL | Tags |
|---|---|
| https://hackerone.com/reports/239719 | x_refsource_MISC |
| https://community.ubnt.com/t5/EdgeMAX-Updates-Blo… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Networks | EdgeRouter X |
Affected:
EdgeOS v1.9.1.1 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T13:25:17.095Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://hackerone.com/reports/239719"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EdgeRouter X",
"vendor": "Ubiquiti Networks",
"versions": [
{
"status": "affected",
"version": "EdgeOS v1.9.1.1 and prior"
}
]
}
],
"datePublic": "2017-09-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of validation on the input of the Feature functionality. An attacker with access to an operator (read-only) account and ssh connection to the devices could escalate privileges to admin (root) access in the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "Improper Privilege Management (CWE-269)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-22T13:57:01.000Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://hackerone.com/reports/239719"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"DATE_PUBLIC": "2017-09-06T00:00:00",
"ID": "CVE-2017-0932",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EdgeRouter X",
"version": {
"version_data": [
{
"version_value": "EdgeOS v1.9.1.1 and prior"
}
]
}
}
]
},
"vendor_name": "Ubiquiti Networks"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of validation on the input of the Feature functionality. An attacker with access to an operator (read-only) account and ssh connection to the devices could escalate privileges to admin (root) access in the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Privilege Management (CWE-269)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://hackerone.com/reports/239719",
"refsource": "MISC",
"url": "https://hackerone.com/reports/239719"
},
{
"name": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117",
"refsource": "CONFIRM",
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2017-0932",
"datePublished": "2018-03-22T14:00:00.000Z",
"dateReserved": "2016-11-30T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:27:44.980Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-0934 (GCVE-0-2017-0934)
Vulnerability from cvelistv5 – Published: 2018-03-22 14:00 – Updated: 2024-09-17 04:23- CWE-269 - Improper Privilege Management (CWE-269)
| URL | Tags |
|---|---|
| https://hackerone.com/reports/241044 | x_refsource_MISC |
| https://community.ubnt.com/t5/EdgeMAX-Updates-Blo… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Networks | EdgeRouter X |
Affected:
EdgeOS v1.9.1 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T13:25:17.084Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://hackerone.com/reports/241044"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EdgeRouter X",
"vendor": "Ubiquiti Networks",
"versions": [
{
"status": "affected",
"version": "EdgeOS v1.9.1 and prior"
}
]
}
],
"datePublic": "2017-05-01T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "Improper Privilege Management (CWE-269)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-22T13:57:01.000Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://hackerone.com/reports/241044"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"DATE_PUBLIC": "2017-05-01T00:00:00",
"ID": "CVE-2017-0934",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EdgeRouter X",
"version": {
"version_data": [
{
"version_value": "EdgeOS v1.9.1 and prior"
}
]
}
}
]
},
"vendor_name": "Ubiquiti Networks"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Ubiquiti Networks EdgeOS version 1.9.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Privilege Management (CWE-269)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://hackerone.com/reports/241044",
"refsource": "MISC",
"url": "https://hackerone.com/reports/241044"
},
{
"name": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524",
"refsource": "CONFIRM",
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-release-v1-9-1-1/ba-p/1910524"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2017-0934",
"datePublished": "2018-03-22T14:00:00.000Z",
"dateReserved": "2016-11-30T00:00:00.000Z",
"dateUpdated": "2024-09-17T04:23:56.390Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-0935 (GCVE-0-2017-0935)
Vulnerability from cvelistv5 – Published: 2018-03-22 14:00 – Updated: 2024-09-17 01:11- CWE-269 - Improper Privilege Management (CWE-269)
| URL | Tags |
|---|---|
| https://hackerone.com/reports/242407 | x_refsource_MISC |
| https://community.ubnt.com/t5/EdgeMAX-Updates-Blo… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Ubiquiti Networks | EdgeRouter X |
Affected:
EdgeOS v1.9.1.1 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T13:25:17.246Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://hackerone.com/reports/242407"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EdgeRouter X",
"vendor": "Ubiquiti Networks",
"versions": [
{
"status": "affected",
"version": "EdgeOS v1.9.1.1 and prior"
}
]
}
],
"datePublic": "2017-09-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "Improper Privilege Management (CWE-269)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-22T13:57:01.000Z",
"orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"shortName": "hackerone"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://hackerone.com/reports/242407"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "support@hackerone.com",
"DATE_PUBLIC": "2017-09-06T00:00:00",
"ID": "CVE-2017-0935",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EdgeRouter X",
"version": {
"version_data": [
{
"version_value": "EdgeOS v1.9.1.1 and prior"
}
]
}
}
]
},
"vendor_name": "Ubiquiti Networks"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Ubiquiti Networks EdgeOS version 1.9.1.1 and prior suffer from an Improper Privilege Management vulnerability due to the lack of protection of the file system leading to sensitive information being exposed. An attacker with access to an operator (read-only) account could escalate privileges to admin (root) access in the system."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Privilege Management (CWE-269)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://hackerone.com/reports/242407",
"refsource": "MISC",
"url": "https://hackerone.com/reports/242407"
},
{
"name": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117",
"refsource": "CONFIRM",
"url": "https://community.ubnt.com/t5/EdgeMAX-Updates-Blog/EdgeMAX-EdgeRouter-software-security-release-v1-9-7-hotfix-3/ba-p/2054117"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
"assignerShortName": "hackerone",
"cveId": "CVE-2017-0935",
"datePublished": "2018-03-22T14:00:00.000Z",
"dateReserved": "2016-11-30T00:00:00.000Z",
"dateUpdated": "2024-09-17T01:11:19.422Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-12728 (GCVE-0-2017-12728)
Vulnerability from cvelistv5 – Published: 2017-10-04 07:00 – Updated: 2024-08-05 18:43| URL | Tags |
|---|---|
| https://ics-cert.us-cert.gov/advisories/ICSA-17-250-01 | x_refsource_MISC |
| http://www.securityfocus.com/bid/100668 | vdb-entryx_refsource_BID |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | SpiderControl SCADA Web Server |
Affected:
SpiderControl SCADA Web Server
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T18:43:56.611Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-250-01"
},
{
"name": "100668",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/100668"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SpiderControl SCADA Web Server",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "SpiderControl SCADA Web Server"
}
]
}
],
"datePublic": "2017-10-04T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the context of the current system services."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-10-04T09:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-250-01"
},
{
"name": "100668",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/100668"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2017-12728",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SpiderControl SCADA Web Server",
"version": {
"version_data": [
{
"version_value": "SpiderControl SCADA Web Server"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Improper Privilege Management issue was discovered in SpiderControl SCADA Web Server Version 2.02.0007 and prior. Authenticated, non-administrative local users are able to alter service executables with escalated privileges, which could allow an attacker to execute arbitrary code under the context of the current system services."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-250-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-250-01"
},
{
"name": "100668",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/100668"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2017-12728",
"datePublished": "2017-10-04T07:00:00.000Z",
"dateReserved": "2017-08-09T00:00:00.000Z",
"dateUpdated": "2024-08-05T18:43:56.611Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-20021 (GCVE-0-2017-20021)
Vulnerability from cvelistv5 – Published: 2022-06-09 22:35 – Updated: 2025-04-15 14:29- CWE-269 - Improper Privilege Management
| URL | Tags |
|---|---|
| http://seclists.org/fulldisclosure/2017/Mar/58 | x_refsource_MISC |
| https://vuldb.com/?id.98931 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T21:45:24.669Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2017/Mar/58"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://vuldb.com/?id.98931"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-20021",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-14T16:56:29.344061Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T14:29:58.849Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Solar-Log",
"vendor": "Solare",
"versions": [
{
"status": "affected",
"version": "2.8.4-56"
},
{
"status": "affected",
"version": "3.5.2-85"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "T. Weber"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Solare Solar-Log 2.8.4-56/3.5.2-85. This affects an unknown part of the component File Upload. The manipulation leads to privilege escalation. It is possible to initiate the attack remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-09T22:35:54.000Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://seclists.org/fulldisclosure/2017/Mar/58"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://vuldb.com/?id.98931"
}
],
"title": "Solare Solar-Log File Upload privileges management",
"x_generator": "vuldb.com",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cna@vuldb.com",
"ID": "CVE-2017-20021",
"REQUESTER": "cna@vuldb.com",
"STATE": "PUBLIC",
"TITLE": "Solare Solar-Log File Upload privileges management"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Solar-Log",
"version": {
"version_data": [
{
"version_value": "2.8.4-56"
},
{
"version_value": "3.5.2-85"
}
]
}
}
]
},
"vendor_name": "Solare"
}
]
}
},
"credit": "T. Weber",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability, which was classified as critical, was found in Solare Solar-Log 2.8.4-56/3.5.2-85. This affects an unknown part of the component File Upload. The manipulation leads to privilege escalation. It is possible to initiate the attack remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component."
}
]
},
"generator": "vuldb.com",
"impact": {
"cvss": {
"baseScore": "6.5",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269 Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://seclists.org/fulldisclosure/2017/Mar/58",
"refsource": "MISC",
"url": "http://seclists.org/fulldisclosure/2017/Mar/58"
},
{
"name": "https://vuldb.com/?id.98931",
"refsource": "MISC",
"url": "https://vuldb.com/?id.98931"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2017-20021",
"datePublished": "2022-06-09T22:35:54.000Z",
"dateReserved": "2022-06-05T00:00:00.000Z",
"dateUpdated": "2025-04-15T14:29:58.849Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-20023 (GCVE-0-2017-20023)
Vulnerability from cvelistv5 – Published: 2022-06-09 22:35 – Updated: 2025-04-15 14:29- CWE-269 - Improper Privilege Management
| URL | Tags |
|---|---|
| http://seclists.org/fulldisclosure/2017/Mar/58 | x_refsource_MISC |
| https://vuldb.com/?id.98933 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T21:45:24.624Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2017/Mar/58"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://vuldb.com/?id.98933"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-20023",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-14T17:12:31.199508Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T14:29:43.295Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Solar-Log",
"vendor": "Solare",
"versions": [
{
"status": "affected",
"version": "2.8.4-56"
},
{
"status": "affected",
"version": "3.5.2-85"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "T. Weber"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Solare Solar-Log 2.8.4-56/3.5.2-85 and classified as critical. This issue affects some unknown processing of the component Network Config. The manipulation leads to privilege escalation. The attack may be initiated remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-09T22:35:57.000Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://seclists.org/fulldisclosure/2017/Mar/58"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://vuldb.com/?id.98933"
}
],
"title": "Solare Solar-Log Network Config privileges management",
"x_generator": "vuldb.com",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cna@vuldb.com",
"ID": "CVE-2017-20023",
"REQUESTER": "cna@vuldb.com",
"STATE": "PUBLIC",
"TITLE": "Solare Solar-Log Network Config privileges management"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Solar-Log",
"version": {
"version_data": [
{
"version_value": "2.8.4-56"
},
{
"version_value": "3.5.2-85"
}
]
}
}
]
},
"vendor_name": "Solare"
}
]
}
},
"credit": "T. Weber",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was found in Solare Solar-Log 2.8.4-56/3.5.2-85 and classified as critical. This issue affects some unknown processing of the component Network Config. The manipulation leads to privilege escalation. The attack may be initiated remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component."
}
]
},
"generator": "vuldb.com",
"impact": {
"cvss": {
"baseScore": "6.3",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269 Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://seclists.org/fulldisclosure/2017/Mar/58",
"refsource": "MISC",
"url": "http://seclists.org/fulldisclosure/2017/Mar/58"
},
{
"name": "https://vuldb.com/?id.98933",
"refsource": "MISC",
"url": "https://vuldb.com/?id.98933"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2017-20023",
"datePublished": "2022-06-09T22:35:57.000Z",
"dateReserved": "2022-06-05T00:00:00.000Z",
"dateUpdated": "2025-04-15T14:29:43.295Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-20025 (GCVE-0-2017-20025)
Vulnerability from cvelistv5 – Published: 2022-06-09 22:36 – Updated: 2025-04-15 14:29- CWE-269 - Improper Privilege Management
| URL | Tags |
|---|---|
| http://seclists.org/fulldisclosure/2017/Mar/58 | x_refsource_MISC |
| https://vuldb.com/?id.98935 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T21:45:24.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2017/Mar/58"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://vuldb.com/?id.98935"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-20025",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-14T16:56:22.988042Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T14:29:19.711Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Solar-Log",
"vendor": "Solare",
"versions": [
{
"status": "affected",
"version": "2.8.4-56"
},
{
"status": "affected",
"version": "3.5.2-85"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "T. Weber"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in Solare Solar-Log 2.8.4-56/3.5.2-85. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component Flash Memory. The manipulation leads to privilege escalation. The attack can be launched remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-09T22:36:00.000Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://seclists.org/fulldisclosure/2017/Mar/58"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://vuldb.com/?id.98935"
}
],
"title": "Solare Solar-Log Flash Memory privileges management",
"x_generator": "vuldb.com",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cna@vuldb.com",
"ID": "CVE-2017-20025",
"REQUESTER": "cna@vuldb.com",
"STATE": "PUBLIC",
"TITLE": "Solare Solar-Log Flash Memory privileges management"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Solar-Log",
"version": {
"version_data": [
{
"version_value": "2.8.4-56"
},
{
"version_value": "3.5.2-85"
}
]
}
}
]
},
"vendor_name": "Solare"
}
]
}
},
"credit": "T. Weber",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was found in Solare Solar-Log 2.8.4-56/3.5.2-85. It has been declared as critical. Affected by this vulnerability is an unknown functionality of the component Flash Memory. The manipulation leads to privilege escalation. The attack can be launched remotely. Upgrading to version 3.5.3-86 is able to address this issue. It is recommended to upgrade the affected component."
}
]
},
"generator": "vuldb.com",
"impact": {
"cvss": {
"baseScore": "7.3",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269 Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://seclists.org/fulldisclosure/2017/Mar/58",
"refsource": "MISC",
"url": "http://seclists.org/fulldisclosure/2017/Mar/58"
},
{
"name": "https://vuldb.com/?id.98935",
"refsource": "MISC",
"url": "https://vuldb.com/?id.98935"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2017-20025",
"datePublished": "2022-06-09T22:36:00.000Z",
"dateReserved": "2022-06-05T00:00:00.000Z",
"dateUpdated": "2025-04-15T14:29:19.711Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-20028 (GCVE-0-2017-20028)
Vulnerability from cvelistv5 – Published: 2022-06-09 22:36 – Updated: 2025-04-15 14:28- CWE-269 - Improper Privilege Management
| URL | Tags |
|---|---|
| http://seclists.org/fulldisclosure/2017/Mar/48 | x_refsource_MISC |
| https://vuldb.com/?id.98925 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| unspecified | HumHub |
Affected:
0.20.1
Affected: 1.0.0-beta.3 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T21:45:24.570Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2017/Mar/48"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://vuldb.com/?id.98925"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-20028",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-14T17:13:32.357442Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T14:28:51.461Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "HumHub",
"vendor": "unspecified",
"versions": [
{
"status": "affected",
"version": "0.20.1"
},
{
"status": "affected",
"version": "1.0.0-beta.3"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Tim Coen"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in HumHub 0.20.1/1.0.0-beta.3. It has been classified as critical. This affects an unknown part. The manipulation leads to privilege escalation. It is possible to initiate the attack remotely. Upgrading to version 1.0.0 is able to address this issue. It is recommended to upgrade the affected component."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-09T22:36:05.000Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://seclists.org/fulldisclosure/2017/Mar/48"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://vuldb.com/?id.98925"
}
],
"title": "HumHub privileges management",
"x_generator": "vuldb.com",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cna@vuldb.com",
"ID": "CVE-2017-20028",
"REQUESTER": "cna@vuldb.com",
"STATE": "PUBLIC",
"TITLE": "HumHub privileges management"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HumHub",
"version": {
"version_data": [
{
"version_value": "0.20.1"
},
{
"version_value": "1.0.0-beta.3"
}
]
}
}
]
},
"vendor_name": ""
}
]
}
},
"credit": "Tim Coen",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was found in HumHub 0.20.1/1.0.0-beta.3. It has been classified as critical. This affects an unknown part. The manipulation leads to privilege escalation. It is possible to initiate the attack remotely. Upgrading to version 1.0.0 is able to address this issue. It is recommended to upgrade the affected component."
}
]
},
"generator": "vuldb.com",
"impact": {
"cvss": {
"baseScore": "5.6",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269 Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://seclists.org/fulldisclosure/2017/Mar/48",
"refsource": "MISC",
"url": "http://seclists.org/fulldisclosure/2017/Mar/48"
},
{
"name": "https://vuldb.com/?id.98925",
"refsource": "MISC",
"url": "https://vuldb.com/?id.98925"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2017-20028",
"datePublished": "2022-06-09T22:36:05.000Z",
"dateReserved": "2022-06-05T00:00:00.000Z",
"dateUpdated": "2025-04-15T14:28:51.461Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-20037 (GCVE-0-2017-20037)
Vulnerability from cvelistv5 – Published: 2022-06-11 10:00 – Updated: 2025-04-15 14:27- CWE-269 - Improper Privilege Management
| URL | Tags |
|---|---|
| http://seclists.org/fulldisclosure/2017/Mar/25 | x_refsource_MISC |
| https://vuldb.com/?id.98905 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| SICUNET | Access Controller |
Affected:
0.32-05z
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T21:45:24.596Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2017/Mar/25"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://vuldb.com/?id.98905"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-20037",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-14T17:13:29.159071Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T14:27:16.117Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Access Controller",
"vendor": "SICUNET",
"versions": [
{
"status": "affected",
"version": "0.32-05z"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Andrew Griffiths"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in SICUNET Access Controller 0.32-05z and classified as critical. Affected by this vulnerability is an unknown functionality. The manipulation of the argument c leads to privilege escalation. The attack can be launched remotely."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-11T10:00:21.000Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://seclists.org/fulldisclosure/2017/Mar/25"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://vuldb.com/?id.98905"
}
],
"title": "SICUNET Access Controller privileges management",
"x_generator": "vuldb.com",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cna@vuldb.com",
"ID": "CVE-2017-20037",
"REQUESTER": "cna@vuldb.com",
"STATE": "PUBLIC",
"TITLE": "SICUNET Access Controller privileges management"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Access Controller",
"version": {
"version_data": [
{
"version_value": "0.32-05z"
}
]
}
}
]
},
"vendor_name": "SICUNET"
}
]
}
},
"credit": "Andrew Griffiths",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been found in SICUNET Access Controller 0.32-05z and classified as critical. Affected by this vulnerability is an unknown functionality. The manipulation of the argument c leads to privilege escalation. The attack can be launched remotely."
}
]
},
"generator": "vuldb.com",
"impact": {
"cvss": {
"baseScore": "6.3",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269 Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://seclists.org/fulldisclosure/2017/Mar/25",
"refsource": "MISC",
"url": "http://seclists.org/fulldisclosure/2017/Mar/25"
},
{
"name": "https://vuldb.com/?id.98905",
"refsource": "MISC",
"url": "https://vuldb.com/?id.98905"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2017-20037",
"datePublished": "2022-06-11T10:00:21.000Z",
"dateReserved": "2022-06-05T00:00:00.000Z",
"dateUpdated": "2025-04-15T14:27:16.117Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2017-20038 (GCVE-0-2017-20038)
Vulnerability from cvelistv5 – Published: 2022-06-11 10:00 – Updated: 2025-04-15 14:27- CWE-269 - Improper Privilege Management
| URL | Tags |
|---|---|
| http://seclists.org/fulldisclosure/2017/Mar/25 | x_refsource_MISC |
| https://vuldb.com/?id.98906 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| SICUNET | Access Controller |
Affected:
0.32-05z
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T21:45:25.198Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2017/Mar/25"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://vuldb.com/?id.98906"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2017-20038",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-14T17:13:26.147370Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T14:27:05.409Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Access Controller",
"vendor": "SICUNET",
"versions": [
{
"status": "affected",
"version": "0.32-05z"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Andrew Griffiths"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was found in SICUNET Access Controller 0.32-05z and classified as critical. Affected by this issue is some unknown functionality of the file card_scan_decoder.php. The manipulation of the argument No/door leads to privilege escalation. The attack may be launched remotely."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-269",
"description": "CWE-269 Improper Privilege Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-11T10:00:23.000Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://seclists.org/fulldisclosure/2017/Mar/25"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://vuldb.com/?id.98906"
}
],
"title": "SICUNET Access Controller card_scan_decoder.php privileges management",
"x_generator": "vuldb.com",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cna@vuldb.com",
"ID": "CVE-2017-20038",
"REQUESTER": "cna@vuldb.com",
"STATE": "PUBLIC",
"TITLE": "SICUNET Access Controller card_scan_decoder.php privileges management"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Access Controller",
"version": {
"version_data": [
{
"version_value": "0.32-05z"
}
]
}
}
]
},
"vendor_name": "SICUNET"
}
]
}
},
"credit": "Andrew Griffiths",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability was found in SICUNET Access Controller 0.32-05z and classified as critical. Affected by this issue is some unknown functionality of the file card_scan_decoder.php. The manipulation of the argument No/door leads to privilege escalation. The attack may be launched remotely."
}
]
},
"generator": "vuldb.com",
"impact": {
"cvss": {
"baseScore": "6.3",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-269 Improper Privilege Management"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://seclists.org/fulldisclosure/2017/Mar/25",
"refsource": "MISC",
"url": "http://seclists.org/fulldisclosure/2017/Mar/25"
},
{
"name": "https://vuldb.com/?id.98906",
"refsource": "MISC",
"url": "https://vuldb.com/?id.98906"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2017-20038",
"datePublished": "2022-06-11T10:00:23.000Z",
"dateReserved": "2022-06-05T00:00:00.000Z",
"dateUpdated": "2025-04-15T14:27:05.409Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation ID: MIT-1
Phases: Architecture and Design, Operation
Description:
- Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
Mitigation ID: MIT-48
Phase: Architecture and Design
Strategy: Separation of Privilege
Description:
- Follow the principle of least privilege when assigning access rights to entities in a software system.
Mitigation ID: MIT-49
Phase: Architecture and Design
Strategy: Separation of Privilege
Description:
- Consider following the principle of separation of privilege. Require multiple conditions to be met before permitting access to a system resource.
CAPEC-122: Privilege Abuse
An adversary is able to exploit features of the target that should be reserved for privileged users or administrators but are exposed to use by lower or non-privileged accounts. Access to sensitive information and functionality must be controlled to ensure that only authorized users are able to access these resources.
CAPEC-233: Privilege Escalation
An adversary exploits a weakness enabling them to elevate their privilege and perform an action that they are not supposed to be authorized to perform.
CAPEC-58: Restful Privilege Elevation
An adversary identifies a Rest HTTP (Get, Put, Delete) style permission method allowing them to perform various malicious actions upon server data due to lack of access control mechanisms implemented within the application service accepting HTTP messages.