{"metadata": {"vulnerability": "cve-2024-2637", "count": 16, "kinds": {"milestone": 4, "sighting": 1, "kev": 0, "other": 11}, "linked_omitted": 0}, "data": [{"timestamp": "2024-03-19T08:15:24.368Z", "date_only": false, "value": "2024-03-19T08:15:24.368Z", "kind": "milestone", "label": "Reserved", "source": "cvelistv5", "record": "cve-2024-2637", "field": "cveMetadata.dateReserved"}, {"timestamp": "2024-04-02T05:02:53.052Z", "date_only": false, "value": "2024-04-02T05:02:53.052981Z", "kind": "other", "label": "Updated", "source": "gsd \u00b7 GSD-2024-2637", "record": "GSD-2024-2637", "field": "gsd.osvSchema.modified", "linked_record": true}, {"timestamp": "2024-05-14T18:49:28.624Z", "date_only": false, "value": "2024-05-14T18:49:28.624Z", "kind": "milestone", "label": "Published", "source": "cvelistv5", "record": "cve-2024-2637", "field": "cveMetadata.datePublished", "metric_role": "disclosure", "metric_basis": "recorded_event"}, {"timestamp": "2024-05-14T19:15:10Z", "date_only": false, "value": "2024-05-14T19:15:10Z", "kind": "other", "label": "Nvd published at", "source": "github \u00b7 GHSA-JC5J-VX46-FPGV", "record": "GHSA-JC5J-VX46-FPGV", "field": "database_specific.nvd_published_at", "linked_record": true}, {"timestamp": "2024-05-14T19:15:10.230Z", "date_only": false, "value": "2024-05-14T19:15:10.230", "kind": "milestone", "label": "Published", "source": "fkie_nvd \u00b7 FKIE_CVE-2024-2637", "record": "FKIE_CVE-2024-2637", "field": "published", "metric_role": "disclosure", "metric_basis": "recorded_event", "linked_record": true}, {"timestamp": "2024-05-14T19:33:12.195Z", "date_only": false, "value": "2024-05-14T19:33:12.195778Z", "kind": "other", "label": "Recorded", "source": "cvelistv5 / CISA-ADP", "record": "cve-2024-2637", "field": "containers.adp.0.metrics.0.other.content.timestamp"}, {"timestamp": "2024-05-14T19:33:12.195Z", "date_only": false, "value": "2024-05-14T19:33:12.195778Z", "kind": "other", "label": "Recorded", "source": "fkie_nvd \u00b7 FKIE_CVE-2024-2637", "record": "FKIE_CVE-2024-2637", "field": "metrics.ssvcV203.0.ssvcData.timestamp", "linked_record": true}, {"timestamp": "2024-05-14T21:34:44Z", "date_only": false, "value": "2024-05-14T21:34:44Z", "kind": "milestone", "label": "Published", "source": "github \u00b7 GHSA-JC5J-VX46-FPGV", "record": "GHSA-JC5J-VX46-FPGV", "field": "published", "metric_role": "disclosure", "metric_basis": "recorded_event", "linked_record": true}, {"timestamp": "2024-06-06T14:56:12.677Z", "date_only": false, "value": "2024-06-06T14:56:12.677Z", "kind": "other", "label": "Updated", "source": "cvelistv5 / CISA-ADP", "record": "cve-2024-2637", "field": "containers.adp.0.providerMetadata.dateUpdated"}, {"timestamp": "2024-08-01T19:18:48.124Z", "date_only": false, "value": "2024-08-01T19:18:48.124Z", "kind": "other", "label": "Updated", "source": "cvelistv5 / CVE", "record": "cve-2024-2637", "field": "containers.adp.1.providerMetadata.dateUpdated"}, {"timestamp": "2025-04-02T18:50:00Z", "date_only": false, "value": "2025-04-02T18:50:00.000Z", "kind": "other", "label": "Made public", "source": "cvelistv5 / ABB", "record": "cve-2024-2637", "field": "containers.cna.datePublic", "metric_role": "disclosure", "metric_basis": "recorded_event"}, {"timestamp": "2025-04-24T06:52:46.092Z", "date_only": false, "value": "2025-04-24T06:52:46.092Z", "kind": "other", "label": "Updated", "source": "cvelistv5", "record": "cve-2024-2637", "field": "cveMetadata.dateUpdated"}, {"timestamp": "2025-04-24T06:52:46.092Z", "date_only": false, "value": "2025-04-24T06:52:46.092Z", "kind": "other", "label": "Updated", "source": "cvelistv5 / ABB", "record": "cve-2024-2637", "field": "containers.cna.providerMetadata.dateUpdated"}, {"timestamp": "2025-04-24T07:19:22Z", "date_only": false, "value": "2025-04-24T07:19:22.000000Z", "kind": "sighting", "label": "Published proof of concept", "source": "https://t.me/DarkWebInformer_CVEAlerts/13193", "record": "CVE-2024-2637", "field": "creation_timestamp", "uuid": "b92f121c-1623-4d29-a3bb-8c434d1be909", "content": "\ud83d\udd17 DarkWebInformer.com - Cyber Threat Intelligence\n\ud83d\udccc CVE ID: CVE-2024-2637\n\ud83d\udd25 CVSS Score: 7.2 (cvssV3_1, Vector: CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H)\n\ud83d\udd39 Description: An Uncontrolled Search Path Element vulnerability\u00a0in B&amp;R Industrial Automation Scene Viewer, B&amp;R Industrial Automation Automation Runtime, B&amp;R Industrial Automation mapp Vision, B&amp;R Industrial Automation mapp View, B&amp;R Industrial Automation mapp Cockpit, B&amp;R Industrial Automation mapp Safety, B&amp;R Industrial Automation VC4, B&amp;R Industrial Automation APROL, B&amp;R Industrial Automation CAN Driver, B&amp;R Industrial Automation CAN Driver CC770, B&amp;R Industrial Automation CAN Driver SJA1000, B&amp;R Industrial Automation Tou0ch Lock, B&amp;R Industrial Automation B&amp;R Single-Touch Driver, B&amp;R Industrial Automation Serial User Mode Touch Driver, B&amp;R Industrial Automation Windows Settings Changer (LTSC), B&amp;R Industrial Automation Windows Settings Changer (2019 LTSC), B&amp;R Industrial Automation Windows 10 Recovery Solution, B&amp;R Industrial Automation ADI driver universal, B&amp;R Industrial Automation ADI Development Kit, B&amp;R Industrial Automation ADI .NET SDK, B&amp;R Industrial Automation SRAM driver, B&amp;R Industrial Automation HMI Service Center, B&amp;R Industrial Automation HMI Service Center Maintenance, B&amp;R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC, B&amp;R Industrial Automation KCF Editor could allow an authenticated local attacker to execute malicious code by placing specially crafted files in the loading search path..This issue affects Scene Viewer: before 4.4.0; Automation Runtime: before J4.93; mapp Vision: before 5.26.1; mapp View: before 5.24.2; mapp Cockpit: before 5.24.2; mapp Safety: before 5.24.2; VC4: before 4.73.2; APROL: before 4.4-01; CAN Driver: before 1.1.0; CAN Driver CC770: before 3.3.0; CAN Driver SJA1000: before 1.3.0; Tou0ch Lock: before 2.1.0; B&amp;R Single-Touch Driver: before 2.0.0; Serial User Mode Touch Driver: before 1.7.1; Windows Settings Changer (LTSC): before 3.2.0; Windows Settings Changer (2019 LTSC): before 2.2.0; Windows 10 Recovery Solution: before 3.2.0; ADI driver universal: before 3.2.0; ADI Development Kit: before 5.5.0; ADI .NET SDK: before 4.1.0; SRAM driver: before 1.2.0; HMI Service Center: before 3.1.0; HMI Service Center Maintenance: before 2.1.0; Windows 10 IoT Enterprise 2019 LTSC: through 1.1; KCF Editor: before 1.1.0.\n\ud83d\udccf Published: 2024-05-14T18:49:28.624Z\n\ud83d\udccf Modified: 2025-04-24T06:52:46.092Z\n\ud83d\udd17 References:\n1. https://www.br-automation.com/fileadmin/SA24P005_Insecure_Loading_of_Code-c7d9e49c.pdf", "url": "https://t.me/DarkWebInformer_CVEAlerts/13193", "metric_role": "exploit_publication", "metric_basis": "sighting_report"}, {"timestamp": "2025-04-24T09:30:33Z", "date_only": false, "value": "2025-04-24T09:30:33Z", "kind": "other", "label": "Updated", "source": "github \u00b7 GHSA-JC5J-VX46-FPGV", "record": "GHSA-JC5J-VX46-FPGV", "field": "modified", "linked_record": true}, {"timestamp": "2026-06-17T07:24:56.563Z", "date_only": false, "value": "2026-06-17T07:24:56.563", "kind": "other", "label": "Updated", "source": "fkie_nvd \u00b7 FKIE_CVE-2024-2637", "record": "FKIE_CVE-2024-2637", "field": "lastModified", "linked_record": true}], "metrics": {"as_of": "2026-11-27T15:36:27.501Z", "anchors": {"origin": {"timestamp": "2024-05-14T18:49:28.624Z", "date_only": false, "value": "2024-05-14T18:49:28.624Z", "kind": "milestone", "label": "Published", "source": "cvelistv5", "record": "cve-2024-2637", "field": "cveMetadata.datePublished", "metric_role": "disclosure", "metric_basis": "recorded_event"}, "discovery": null, "report": null, "acknowledgement": null, "disclosure": {"timestamp": "2024-05-14T18:49:28.624Z", "date_only": false, "value": "2024-05-14T18:49:28.624Z", "kind": "milestone", "label": "Published", "source": "cvelistv5", "record": "cve-2024-2637", "field": "cveMetadata.datePublished", "metric_role": "disclosure", "metric_basis": "recorded_event"}, "exploit_publication": {"timestamp": "2025-04-24T07:19:22Z", "date_only": false, "value": "2025-04-24T07:19:22.000000Z", "kind": "sighting", "label": "Published proof of concept", "source": "https://t.me/DarkWebInformer_CVEAlerts/13193", "record": "CVE-2024-2637", "field": "creation_timestamp", "uuid": "b92f121c-1623-4d29-a3bb-8c434d1be909", "content": "\ud83d\udd17 DarkWebInformer.com - Cyber Threat Intelligence\n\ud83d\udccc CVE ID: CVE-2024-2637\n\ud83d\udd25 CVSS Score: 7.2 (cvssV3_1, Vector: CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H)\n\ud83d\udd39 Description: An Uncontrolled Search Path Element vulnerability\u00a0in B&amp;R Industrial Automation Scene Viewer, B&amp;R Industrial Automation Automation Runtime, B&amp;R Industrial Automation mapp Vision, B&amp;R Industrial Automation mapp View, B&amp;R Industrial Automation mapp Cockpit, B&amp;R Industrial Automation mapp Safety, B&amp;R Industrial Automation VC4, B&amp;R Industrial Automation APROL, B&amp;R Industrial Automation CAN Driver, B&amp;R Industrial Automation CAN Driver CC770, B&amp;R Industrial Automation CAN Driver SJA1000, B&amp;R Industrial Automation Tou0ch Lock, B&amp;R Industrial Automation B&amp;R Single-Touch Driver, B&amp;R Industrial Automation Serial User Mode Touch Driver, B&amp;R Industrial Automation Windows Settings Changer (LTSC), B&amp;R Industrial Automation Windows Settings Changer (2019 LTSC), B&amp;R Industrial Automation Windows 10 Recovery Solution, B&amp;R Industrial Automation ADI driver universal, B&amp;R Industrial Automation ADI Development Kit, B&amp;R Industrial Automation ADI .NET SDK, B&amp;R Industrial Automation SRAM driver, B&amp;R Industrial Automation HMI Service Center, B&amp;R Industrial Automation HMI Service Center Maintenance, B&amp;R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC, B&amp;R Industrial Automation KCF Editor could allow an authenticated local attacker to execute malicious code by placing specially crafted files in the loading search path..This issue affects Scene Viewer: before 4.4.0; Automation Runtime: before J4.93; mapp Vision: before 5.26.1; mapp View: before 5.24.2; mapp Cockpit: before 5.24.2; mapp Safety: before 5.24.2; VC4: before 4.73.2; APROL: before 4.4-01; CAN Driver: before 1.1.0; CAN Driver CC770: before 3.3.0; CAN Driver SJA1000: before 1.3.0; Tou0ch Lock: before 2.1.0; B&amp;R Single-Touch Driver: before 2.0.0; Serial User Mode Touch Driver: before 1.7.1; Windows Settings Changer (LTSC): before 3.2.0; Windows Settings Changer (2019 LTSC): before 2.2.0; Windows 10 Recovery Solution: before 3.2.0; ADI driver universal: before 3.2.0; ADI Development Kit: before 5.5.0; ADI .NET SDK: before 4.1.0; SRAM driver: before 1.2.0; HMI Service Center: before 3.1.0; HMI Service Center Maintenance: before 2.1.0; Windows 10 IoT Enterprise 2019 LTSC: through 1.1; KCF Editor: before 1.1.0.\n\ud83d\udccf Published: 2024-05-14T18:49:28.624Z\n\ud83d\udccf Modified: 2025-04-24T06:52:46.092Z\n\ud83d\udd17 References:\n1. https://www.br-automation.com/fileadmin/SA24P005_Insecure_Loading_of_Code-c7d9e49c.pdf", "url": "https://t.me/DarkWebInformer_CVEAlerts/13193", "metric_role": "exploit_publication", "metric_basis": "sighting_report"}, "exploitation": null, "patch": null}, "vendor_response_time": {"available": false, "missing": ["start", "end"]}, "time_to_exploit": {"available": false, "missing": ["end"]}, "disclosure_to_exploit": {"available": false, "missing": ["end"]}, "disclosure_to_exploit_publication": {"available": true, "seconds": 29766593.376, "hours": 8268.49816, "days": 344.52075666666667, "min_seconds": 29766593.376, "max_seconds": 29766593.376, "approximate": false, "ongoing": false, "order_known": true, "batch_listing": false, "end_before_start": false, "start": {"timestamp": "2024-05-14T18:49:28.624Z", "date_only": false, "value": "2024-05-14T18:49:28.624Z", "kind": "milestone", "label": "Published", "source": "cvelistv5", "record": "cve-2024-2637", "field": "cveMetadata.datePublished", "metric_role": "disclosure", "metric_basis": "recorded_event"}, "end": {"timestamp": "2025-04-24T07:19:22Z", "date_only": false, "value": "2025-04-24T07:19:22.000000Z", "kind": "sighting", "label": "Published proof of concept", "source": "https://t.me/DarkWebInformer_CVEAlerts/13193", "record": "CVE-2024-2637", "field": "creation_timestamp", "uuid": "b92f121c-1623-4d29-a3bb-8c434d1be909", "content": "\ud83d\udd17 DarkWebInformer.com - Cyber Threat Intelligence\n\ud83d\udccc CVE ID: CVE-2024-2637\n\ud83d\udd25 CVSS Score: 7.2 (cvssV3_1, Vector: CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H)\n\ud83d\udd39 Description: An Uncontrolled Search Path Element vulnerability\u00a0in B&amp;R Industrial Automation Scene Viewer, B&amp;R Industrial Automation Automation Runtime, B&amp;R Industrial Automation mapp Vision, B&amp;R Industrial Automation mapp View, B&amp;R Industrial Automation mapp Cockpit, B&amp;R Industrial Automation mapp Safety, B&amp;R Industrial Automation VC4, B&amp;R Industrial Automation APROL, B&amp;R Industrial Automation CAN Driver, B&amp;R Industrial Automation CAN Driver CC770, B&amp;R Industrial Automation CAN Driver SJA1000, B&amp;R Industrial Automation Tou0ch Lock, B&amp;R Industrial Automation B&amp;R Single-Touch Driver, B&amp;R Industrial Automation Serial User Mode Touch Driver, B&amp;R Industrial Automation Windows Settings Changer (LTSC), B&amp;R Industrial Automation Windows Settings Changer (2019 LTSC), B&amp;R Industrial Automation Windows 10 Recovery Solution, B&amp;R Industrial Automation ADI driver universal, B&amp;R Industrial Automation ADI Development Kit, B&amp;R Industrial Automation ADI .NET SDK, B&amp;R Industrial Automation SRAM driver, B&amp;R Industrial Automation HMI Service Center, B&amp;R Industrial Automation HMI Service Center Maintenance, B&amp;R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC, B&amp;R Industrial Automation KCF Editor could allow an authenticated local attacker to execute malicious code by placing specially crafted files in the loading search path..This issue affects Scene Viewer: before 4.4.0; Automation Runtime: before J4.93; mapp Vision: before 5.26.1; mapp View: before 5.24.2; mapp Cockpit: before 5.24.2; mapp Safety: before 5.24.2; VC4: before 4.73.2; APROL: before 4.4-01; CAN Driver: before 1.1.0; CAN Driver CC770: before 3.3.0; CAN Driver SJA1000: before 1.3.0; Tou0ch Lock: before 2.1.0; B&amp;R Single-Touch Driver: before 2.0.0; Serial User Mode Touch Driver: before 1.7.1; Windows Settings Changer (LTSC): before 3.2.0; Windows Settings Changer (2019 LTSC): before 2.2.0; Windows 10 Recovery Solution: before 3.2.0; ADI driver universal: before 3.2.0; ADI Development Kit: before 5.5.0; ADI .NET SDK: before 4.1.0; SRAM driver: before 1.2.0; HMI Service Center: before 3.1.0; HMI Service Center Maintenance: before 2.1.0; Windows 10 IoT Enterprise 2019 LTSC: through 1.1; KCF Editor: before 1.1.0.\n\ud83d\udccf Published: 2024-05-14T18:49:28.624Z\n\ud83d\udccf Modified: 2025-04-24T06:52:46.092Z\n\ud83d\udd17 References:\n1. https://www.br-automation.com/fileadmin/SA24P005_Insecure_Loading_of_Code-c7d9e49c.pdf", "url": "https://t.me/DarkWebInformer_CVEAlerts/13193", "metric_role": "exploit_publication", "metric_basis": "sighting_report"}}, "time_to_patch": {"available": false, "missing": ["start", "end"]}, "total_time_to_patch": {"available": false, "missing": ["start", "end"]}, "disclosure_to_patch": {"available": false, "missing": ["end"]}, "time_unpatched": {"available": true, "seconds": 80081218.877099, "hours": 22244.78302141639, "days": 926.8659592256829, "min_seconds": 80081218.877099, "max_seconds": 80081218.877099, "approximate": false, "ongoing": true, "order_known": true, "batch_listing": false, "end_before_start": false, "start": {"timestamp": "2024-05-14T18:49:28.624Z", "date_only": false, "value": "2024-05-14T18:49:28.624Z", "kind": "milestone", "label": "Published", "source": "cvelistv5", "record": "cve-2024-2637", "field": "cveMetadata.datePublished", "metric_role": "disclosure", "metric_basis": "recorded_event"}, "end": {"timestamp": "2026-11-27T15:36:27.501Z", "date_only": false, "label": "As of", "source": "Calculation clock"}}, "exploitation_to_patch": {"available": false, "missing": ["start"]}, "exploit_publication_to_patch": {"available": true, "seconds": 50314625.501099, "hours": 13976.284861416389, "days": 582.3452025590162, "min_seconds": 50314625.501099, "max_seconds": 50314625.501099, "approximate": false, "ongoing": true, "order_known": true, "batch_listing": false, "end_before_start": false, "start": {"timestamp": "2025-04-24T07:19:22Z", "date_only": false, "value": "2025-04-24T07:19:22.000000Z", "kind": "sighting", "label": "Published proof of concept", "source": "https://t.me/DarkWebInformer_CVEAlerts/13193", "record": "CVE-2024-2637", "field": "creation_timestamp", "uuid": "b92f121c-1623-4d29-a3bb-8c434d1be909", "content": "\ud83d\udd17 DarkWebInformer.com - Cyber Threat Intelligence\n\ud83d\udccc CVE ID: CVE-2024-2637\n\ud83d\udd25 CVSS Score: 7.2 (cvssV3_1, Vector: CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H)\n\ud83d\udd39 Description: An Uncontrolled Search Path Element vulnerability\u00a0in B&amp;R Industrial Automation Scene Viewer, B&amp;R Industrial Automation Automation Runtime, B&amp;R Industrial Automation mapp Vision, B&amp;R Industrial Automation mapp View, B&amp;R Industrial Automation mapp Cockpit, B&amp;R Industrial Automation mapp Safety, B&amp;R Industrial Automation VC4, B&amp;R Industrial Automation APROL, B&amp;R Industrial Automation CAN Driver, B&amp;R Industrial Automation CAN Driver CC770, B&amp;R Industrial Automation CAN Driver SJA1000, B&amp;R Industrial Automation Tou0ch Lock, B&amp;R Industrial Automation B&amp;R Single-Touch Driver, B&amp;R Industrial Automation Serial User Mode Touch Driver, B&amp;R Industrial Automation Windows Settings Changer (LTSC), B&amp;R Industrial Automation Windows Settings Changer (2019 LTSC), B&amp;R Industrial Automation Windows 10 Recovery Solution, B&amp;R Industrial Automation ADI driver universal, B&amp;R Industrial Automation ADI Development Kit, B&amp;R Industrial Automation ADI .NET SDK, B&amp;R Industrial Automation SRAM driver, B&amp;R Industrial Automation HMI Service Center, B&amp;R Industrial Automation HMI Service Center Maintenance, B&amp;R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC, B&amp;R Industrial Automation KCF Editor could allow an authenticated local attacker to execute malicious code by placing specially crafted files in the loading search path..This issue affects Scene Viewer: before 4.4.0; Automation Runtime: before J4.93; mapp Vision: before 5.26.1; mapp View: before 5.24.2; mapp Cockpit: before 5.24.2; mapp Safety: before 5.24.2; VC4: before 4.73.2; APROL: before 4.4-01; CAN Driver: before 1.1.0; CAN Driver CC770: before 3.3.0; CAN Driver SJA1000: before 1.3.0; Tou0ch Lock: before 2.1.0; B&amp;R Single-Touch Driver: before 2.0.0; Serial User Mode Touch Driver: before 1.7.1; Windows Settings Changer (LTSC): before 3.2.0; Windows Settings Changer (2019 LTSC): before 2.2.0; Windows 10 Recovery Solution: before 3.2.0; ADI driver universal: before 3.2.0; ADI Development Kit: before 5.5.0; ADI .NET SDK: before 4.1.0; SRAM driver: before 1.2.0; HMI Service Center: before 3.1.0; HMI Service Center Maintenance: before 2.1.0; Windows 10 IoT Enterprise 2019 LTSC: through 1.1; KCF Editor: before 1.1.0.\n\ud83d\udccf Published: 2024-05-14T18:49:28.624Z\n\ud83d\udccf Modified: 2025-04-24T06:52:46.092Z\n\ud83d\udd17 References:\n1. https://www.br-automation.com/fileadmin/SA24P005_Insecure_Loading_of_Code-c7d9e49c.pdf", "url": "https://t.me/DarkWebInformer_CVEAlerts/13193", "metric_role": "exploit_publication", "metric_basis": "sighting_report"}, "end": {"timestamp": "2026-11-27T15:36:27.501Z", "date_only": false, "label": "As of", "source": "Calculation clock"}}}}
