{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2025-40634", "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516", "state": "PUBLISHED", "assignerShortName": "INCIBE", "dateReserved": "2025-04-16T08:38:09.209Z", "datePublished": "2025-05-20T10:12:16.550Z", "dateUpdated": "2025-05-20T13:30:19.289Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "Link Archer AX50", "vendor": "TP-Link", "versions": [{"lessThan": "1.0.15 build 241203 rel61480", "status": "affected", "version": "0", "versionType": "custom"}]}], "credits": [{"lang": "en", "type": "finder", "value": "V\u00edctor Fresco Perales (@hacefresko)"}], "datePublic": "2025-05-20T10:00:00.000Z", "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "Stack-based buffer overflow vulnerability in the 'conn-indicator' binary running as root on the TP-Link Archer AX50 router, in firmware versions prior to 1.0.15 build 241203 rel61480. This vulnerability allows an attacker to execute arbitrary code on the device over LAN and WAN networks."}], "value": "Stack-based buffer overflow vulnerability in the 'conn-indicator' binary running as root on the TP-Link Archer AX50 router, in firmware versions prior to 1.0.15 build 241203 rel61480. This vulnerability allows an attacker to execute arbitrary code on the device over LAN and WAN networks."}], "metrics": [{"cvssV4_0": {"Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "HIGH", "attackRequirements": "NONE", "attackVector": "NETWORK", "baseScore": 9.2, "baseSeverity": "CRITICAL", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N", "version": "4.0", "vulnAvailabilityImpact": "HIGH", "vulnConfidentialityImpact": "HIGH", "vulnIntegrityImpact": "HIGH", "vulnerabilityResponseEffort": "NOT_DEFINED"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-121", "description": "CWE-121: Stack-based Buffer Overflow", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516", "shortName": "INCIBE", "dateUpdated": "2025-05-20T10:12:16.550Z"}, "references": [{"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/stack-based-buffer-overflow-tp-link-archer-ax50"}], "solutions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "The vulnerability has been fixed by the TP-Link team in firmware version 1.0.15 build 241203 rel61480."}], "value": "The vulnerability has been fixed by the TP-Link team in firmware version 1.0.15 build 241203 rel61480."}], "source": {"discovery": "EXTERNAL"}, "title": "Stack-based buffer overflow in TP-Link Archer AX50", "x_generator": {"engine": "Vulnogram 0.2.0"}, "x_gcve": [{"vulnId": "CVE-2025-40634", "recordType": "advisory"}]}, "adp": [{"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2025-05-20T13:28:08.979231Z", "id": "CVE-2025-40634", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-05-20T13:30:19.289Z"}}]}, "vulnerability-lookup:meta": {"epss": {"cve": "CVE-2025-40634", "date": "2026-11-09", "epss": "0.00682", "percentile": "0.52756"}, "nvd": "{\"cve\":{\"id\":\"CVE-2025-40634\",\"sourceIdentifier\":\"cve-coordination@incibe.es\",\"published\":\"2025-05-20T11:15:48.930\",\"lastModified\":\"2026-06-17T09:21:51.953\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Stack-based buffer overflow vulnerability in the 'conn-indicator' binary running as root on the TP-Link Archer AX50 router, in firmware versions prior to 1.0.15 build 241203 rel61480. This vulnerability allows an attacker to execute arbitrary code on the device over LAN and WAN networks.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de desbordamiento de b\u00fafer en la pila en el binario 'conn-indicator' que se ejecuta como root en el router TP-Link Archer AX50, en versiones de firmware anteriores a la 1.0.15, compilaci\u00f3n 241203, rel61480. Esta vulnerabilidad permite a un atacante ejecutar c\u00f3digo arbitrario en el dispositivo a trav\u00e9s de redes LAN y WAN.\"}],\"affected\":[{\"source\":\"cve-coordination@incibe.es\",\"affectedData\":[{\"vendor\":\"TP-Link\",\"product\":\"Link Archer AX50\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"0\",\"lessThan\":\"1.0.15 build 241203 rel61480\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cve-coordination@incibe.es\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":9.2,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2025-05-20T13:28:08.979231Z\",\"id\":\"CVE-2025-40634\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"cve-coordination@incibe.es\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]}],\"references\":[{\"url\":\"https://www.incibe.es/en/incibe-cert/notices/aviso/stack-based-buffer-overflow-tp-link-archer-ax50\",\"source\":\"cve-coordination@incibe.es\"}]}}", "redhat_vex": {"current_release_date": "2026-01-09T08:45:30+00:00", "cve": "CVE-2025-40634", "id": "CVE-2025-40634", "initial_release_date": "2025-05-20T10:00:00+00:00", "product_status:known_not_affected": "1", "source": "Red Hat CSAF VEX", "status": "final", "title": "Stack-based buffer overflow in TP-Link Archer AX50", "url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-40634.json", "version": "3"}}}