{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"cveId": "CVE-2024-2229", "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "state": "PUBLISHED", "assignerShortName": "schneider", "dateReserved": "2024-03-06T17:07:33.392Z", "datePublished": "2024-03-18T16:08:33.773Z", "dateUpdated": "2024-08-01T19:03:39.361Z"}, "containers": {"cna": {"affected": [{"defaultStatus": "unaffected", "product": "EcoStruxure Power Design - Ecodial", "vendor": "Schneider Electric", "versions": [{"status": "affected", "version": "All Versions NL"}, {"status": "affected", "version": "All Versions INT"}, {"status": "affected", "version": "All Versions FR"}]}], "descriptions": [{"lang": "en", "supportingMedia": [{"base64": false, "type": "text/html", "value": "\n\n\n\n\n\n\n\nCWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code\nexecution when a malicious project file is loaded into the application by a valid user.\n\n\n\n\n\n\n\n"}], "value": "\nCWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code\nexecution when a malicious project file is loaded into the application by a valid user.\n\n"}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1"}, "format": "CVSS", "scenarios": [{"lang": "en", "value": "GENERAL"}]}], "problemTypes": [{"descriptions": [{"cweId": "CWE-502", "description": "CWE-502 Deserialization of Untrusted Data", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider", "dateUpdated": "2024-03-18T16:08:33.773Z"}, "references": [{"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-072-02.pdf"}], "source": {"discovery": "UNKNOWN"}, "x_generator": {"engine": "Vulnogram 0.1.0-dev"}, "x_gcve": [{"vulnId": "CVE-2024-2229", "recordType": "advisory"}]}, "adp": [{"affected": [{"vendor": "schneider-electric", "product": "ecostruxure_power_monitoring_expert", "cpes": ["cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "0", "status": "affected", "lessThanOrEqual": "*", "versionType": "custom"}]}], "metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2024-03-18T16:27:40.910097Z", "id": "CVE-2024-2229", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-06-20T20:59:48.954Z"}}, {"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-01T19:03:39.361Z"}, "title": "CVE Program Container", "references": [{"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-072-02.pdf", "tags": ["x_transferred"]}]}]}, "vulnerability-lookup:meta": {"epss": {"cve": "CVE-2024-2229", "date": "2026-11-08", "epss": "0.00423", "percentile": "0.3689"}, "nvd": "{\"cve\":{\"id\":\"CVE-2024-2229\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2024-03-18T16:15:09.580\",\"lastModified\":\"2026-06-17T07:23:59.630\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nCWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code\\nexecution when a malicious project file is loaded into the application by a valid user.\\n\\n\"},{\"lang\":\"es\",\"value\":\"CWE-502: Existe una vulnerabilidad de deserializaci\u00f3n de datos no confiables que podr\u00eda causar la ejecuci\u00f3n remota de c\u00f3digo cuando un usuario v\u00e1lido carga un archivo de proyecto malicioso en la aplicaci\u00f3n.\"}],\"affected\":[{\"source\":\"cybersecurity@se.com\",\"affectedData\":[{\"vendor\":\"Schneider Electric\",\"product\":\"EcoStruxure Power Design - Ecodial\",\"defaultStatus\":\"unaffected\",\"versions\":[{\"version\":\"All Versions NL\",\"status\":\"affected\"},{\"version\":\"All Versions INT\",\"status\":\"affected\"},{\"version\":\"All Versions FR\",\"status\":\"affected\"}]}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"affectedData\":[{\"vendor\":\"schneider-electric\",\"product\":\"ecostruxure_power_monitoring_expert\",\"defaultStatus\":\"unknown\",\"cpes\":[\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*\"],\"versions\":[{\"version\":\"0\",\"lessThanOrEqual\":\"*\",\"versionType\":\"custom\",\"status\":\"affected\"}]}]}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"ssvcV203\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"ssvcData\":{\"timestamp\":\"2024-03-18T16:27:40.910097Z\",\"id\":\"CVE-2024-2229\",\"options\":[{\"exploitation\":\"none\"},{\"automatable\":\"no\"},{\"technicalImpact\":\"total\"}],\"role\":\"CISA Coordinator\",\"version\":\"2.0.3\"}}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-502\"}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-072-02.pdf\",\"source\":\"cybersecurity@se.com\"},{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-072-02.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}", "redhat_vex": {"current_release_date": "2025-05-28T18:41:59+00:00", "cve": "CVE-2024-2229", "id": "CVE-2024-2229", "initial_release_date": "2024-01-01T00:00:00+00:00", "product_status:known_not_affected": "1", "source": "Red Hat CSAF VEX", "status": "final", "title": "CVE-2024-2229", "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-2229.json", "version": "3"}, "vulnrichment": {"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-072-02.pdf\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T19:03:39.361Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-2229\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-03-18T16:27:40.910097Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*\"], \"vendor\": \"schneider-electric\", \"product\": \"ecostruxure_power_monitoring_expert\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"*\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-06-20T20:59:39.412Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Schneider Electric\", \"product\": \"EcoStruxure Power Design - Ecodial\", \"versions\": [{\"status\": \"affected\", \"version\": \"All Versions NL\"}, {\"status\": \"affected\", \"version\": \"All Versions INT\"}, {\"status\": \"affected\", \"version\": \"All Versions FR\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-072-02.pdf\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nCWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code\\nexecution when a malicious project file is loaded into the application by a valid user.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\\n\\n\\n\\n\\n\\nCWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code\\nexecution when a malicious project file is loaded into the application by a valid user.\\n\\n\\n\\n\\n\\n\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-502\", \"description\": \"CWE-502 Deserialization of Untrusted Data\"}]}], \"providerMetadata\": {\"orgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"shortName\": \"schneider\", \"dateUpdated\": \"2024-03-18T16:08:33.773Z\"}}}", "cveMetadata": "{\"cveId\": \"CVE-2024-2229\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T19:03:39.361Z\", \"dateReserved\": \"2024-03-06T17:07:33.392Z\", \"assignerOrgId\": \"076d1eb6-cfab-4401-b34d-6dfc2a413bdb\", \"datePublished\": \"2024-03-18T16:08:33.773Z\", \"assignerShortName\": \"schneider\"}", "dataType": "CVE_RECORD", "dataVersion": "5.1"}}}